Difference between revisions of "Sonoff Sensor Si7021"
m (→Performance parameters) |
m (→Performance parameters) |
||
Line 47: | Line 47: | ||
| Stability || || — || ≤0.01 || — || ℃/yr | | Stability || || — || ≤0.01 || — || ℃/yr | ||
|} | |} | ||
− | [[File:Si7021_hum_figure_1.jpg| | + | [[File:Si7021_hum_figure_1.jpg|700px]] |
''Figure 1. RH Accuracy at 30℃'' | ''Figure 1. RH Accuracy at 30℃'' | ||
− | [[File:Si7021_temp_figure_2.jpg| | + | [[File:Si7021_temp_figure_2.jpg|700px]] |
''Figure 2. Temperature Accuracy'' | ''Figure 2. Temperature Accuracy'' |
Revision as of 07:51, 21 July 2017
Contents
Overview
Sonoff Si7021 Temperature and Humidity Sensor is a digital temperature and humidity sensor with a calibrated digital signal output. It adopts dedicated digital module acquisition technology and temperature&humidity sensing technology to ensure that the sensor has a very high reliability and excellent long-term stability. The sensor includes an integrated single-chip temperature and humidity sensor chip, which connects to a high-performance 8-bit MCU. The Si7021 sensor has advantages such as excellent quality, ultra-fast response, anti-interference ability and cost-effective. The sensor has 2.5mm 4-pole stereo audio male plug connector, which works perfectly with Sonoff TH10/TH16.
Features
- Relative humidity and temperature measurement
- All calibrated, digital output
- Good long-term stability
- No additional parts required
- Ultra-low energy consumption
- The sensor is fully interchangeable
Electrical Characteristics
Rated Parameters
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Voltage input | VCC | 2.2 | 3.3 | 3.6 | V |
Operating temp. | Ta | -40 | - | +85 | ℃ |
Storage temp. | Ta | -65 | - | +150 | ℃ |
Performance parameters
Parameter | Condition | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Humidity | |||||
Operating range | 0 | — | 100 | %RH | |
Accuracy | 0-80 | — | ±2 | ±3 | %RH |
80-100 | See Figure 1 | ||||
Temperture drift | — | 0.05 | — | %RH/℃ | |
Stability | — | ≤0.25 | — | %RH/yr | |
Temperature | |||||
Operating range | -40 | — | +85 | ℃ | |
Accuracy | -10≤Ta≤85 | — | ±0.3 | ±0.4 | ℃ |
-40≤Ta≤125 | See Figure 2 | ||||
Stability | — | ≤0.01 | — | ℃/yr |
Figure 1. RH Accuracy at 30℃
Figure 2. Temperature Accuracy