Overview
This power module is an isolated-type industrial level power module that can be used in AC-DC power converting. When the situations of over voltage, over current and short circuit appear, this module will help to protect whole device by locking up. What’s more, It can realize isolating the high and low voltage and support AC 85~265V input and DC 5V output.
Go shopping AC-DC Power Module 5V 700mA V2(im141219001)
Feature
- isolate the high and low voltage
- temperature protection, overcurrent protection, short circuit protection
- AC85~265v wide input range
- 431 precise DC5v regulated voltage output
- small size, strong stability, high cost performance
Specification
Voltage Input | AC 85 ~ 265v 50/60HZ |
Voltage Output | DC5V(±0.2V) |
Current Output | 700mA |
Power | 3.5W |
Size | 3*2*1.9cm |
Electronic Characteristics
- Using Environment
Unit | Min | Typical | Max | Test condition | |
Working Temperature | ℃ | -20 | 60 | ||
Relative Humidity | %RH | 40 | 90 | Without cooling |
- Input
Unit | Min | Typical | Max | |
Voltage Input | V ac | 85 | 110/220 | 265 |
Voltage Input | V dc | 100 | 150/300 | 370 |
Current Input | A | 0.0273(AC110V)-0.014(AC220V) | ||
---|---|---|---|---|
Inrush current | A | 20 |
- Output
Voltage output | Minimum current | Maximum current | Peak current | Voltage output range |
+5V | 0A | 700mA | 800mA | 4.80~5.2V |
- Protection
Type | Unit | Y/N | Min | Typical | Max | Status |
Over Voltage | V | 4.8 | 5.2 | Lock and recover after restarting | ||
Over Power | Y | Lock and recover after restarting | ||||
Short Circuit | Y | Auto-recover after troubleshooting | ||||
Temperature | Y | Lock and recover after restarting | ||||
Over Current | Y | Lock and recover after restarting |