Difference between revisions of "4-20mA Sensor Brick"

From ITEAD Wiki
Jump to: navigation, search
m
m
Line 50: Line 50:
 
|-
 
|-
 
|}
 
|}
==The relationship between output voltage and input current in channel 1,2==
 
Output voltage V= 100 * I * 2
 
  
==Installation==
+
*1.When access in type2,3 electronic current loop, please connect JP1 or JP2, both 1In- and 2In- is equal to connecting ground, 1In+ and 2In+ are connected with the current pins to be measured.
*1.When access in type2,3 electronic current loop, please connect the jumper of JP1 or JP2, both 1In- and 2In- is equal to connecting ground, 1In+ and 2In+ are connected with the current pins to be measured.
+
*2.When access in type4 current loop, connect the input end to 1In+ or 2In+, the output end to 1In- or 2In-, and unplug JP1 or JP2 simultaneously.
*2.When access in type4 current loop, connect the input end to 1In+ or 2In+, the output end to 1In- or 2In-, and plug out the jumper of JP1 or JP2 simultaneously.
+
 
 +
==The relationship between output voltage and input current in channel 1,2==
 +
*In theory, their relationship can be describe into this formula: U= 100×I×2
 +
*Note: error ±2% in practical test.

Revision as of 03:15, 30 August 2014

Overview

IM140819001 4.jpg

4~20mA Sensor Brick is an electronic brick module that can be used to test electronic current loop from 4mA to 20mA and support type2,3,4 current output. With a 5V to 24V DC-DC power boost convertor, its max current output can be 150mA, which can be for equipment use.

Features

  • Compatible with the mainstream 2.54 and 4-pin Grove interface in market
  • Compatible with type2,3,4 electronic current loop
  • With use of M4 standard fixed holes, compatible with M4-standard kits such as Lego and Makeblock.

Specification

PCB size 40.6mm X 29mm X 1.6mm
Power supply 5V DC
Compatible interfaces 2.54 4-pin interface and 4-pin Grove interface(1)

Electronic Characteristics

Parameter Min. Typical Max. Unit
Power supply 4.5 5 5.5 VDC
Input measurement current 4 - 20 mA
Output Current(DCDC) - - 150 mA

Hardware

IM140819001pic1.jpg IM140819001pic2.jpg IM140819001pic3.jpg

JP1 JP2
Connected CH1 Type 2/3 CH2 Type 2/3
Disconnected CH1 Type4 CH2 Type4
  • 1.When access in type2,3 electronic current loop, please connect JP1 or JP2, both 1In- and 2In- is equal to connecting ground, 1In+ and 2In+ are connected with the current pins to be measured.
  • 2.When access in type4 current loop, connect the input end to 1In+ or 2In+, the output end to 1In- or 2In-, and unplug JP1 or JP2 simultaneously.

The relationship between output voltage and input current in channel 1,2

  • In theory, their relationship can be describe into this formula: U= 100×I×2
  • Note: error ±2% in practical test.