Line 8: Line 8:
 
=='''Classification I: Operation Commands of Component and System'''==
 
=='''Classification I: Operation Commands of Component and System'''==
  
===<font color="#007FFF">page pageid</font>===
+
===<font color="#007FFF">page: Refresh page</font>===
 +
 
 +
page pageid
 +
 
 
pageid: Page ID or Page Name
 
pageid: Page ID or Page Name
*Instance 1:  
+
 
<pre>page 0        //Refresh the page with page ID of 0</pre>
+
*Example 1:  
*Instance 2:  
+
<pre>page 0        //Refresh page 0</pre>
<pre>page main    //Refresh the page with page name of main
+
*Example 2:  
 +
<pre>page main    //Refresh the page main
 
</pre>
 
</pre>
  
Line 20: Line 24:
 
The device automatically refresh page 0 when power on.
 
The device automatically refresh page 0 when power on.
 
-------------
 
-------------
===<font color="#007FFF">ref cpmID</font>===
 
cpmID: the component to refresh
 
  
*Instance
+
===<font color="#007FFF">ref: Refresh component</font>===
<pre>ref t0  //refresh component t0</pre>
+
 
 +
ref cmpID
 +
 
 +
cmpID: component ID or component name
 +
 
 +
*Example
 +
<pre>ref t0  //refresh component t0
 +
ref 1    // refresh component 1
 +
</pre>
  
 
Remarks:
 
Remarks:
 
            
 
            
The default loading mode is automatically load when you create and edit a component in Nextion Editor. If set it as manually load, you should use ref command to load the component. Or when the component is covered by the other components, you can use this command to refresh the covered component.
+
1. The default loading mode is automatically load when you create and edit a component in Nextion Editor. If set it as manually load, you should use ref command to load the component. Or when the component is covered by the other components, you can use this command to refresh the covered component.
 +
 
 +
2. Component auto refresh when attribute changes only valid for those attributes in green bold font. The other attributes not in this format can only be refreshed and displayed by the command of ref.
 +
 
 +
3.When creating a component in Nextion editor, the default loading mode is auto loading. When the loading mode is set as manual loading, it requires to use ref to load. When the component is sheltered by GUI command mapping, or when the component is sheltered by other manual loading components, you can use ref to refresh the component.
 +
 
 
----------------
 
----------------
  
===<font color="#007FFF">get att</font>===
 
att: Name of Variable
 
  
*Instance 1
+
===<font color="#007FFF">click: Activate component's press/release event</font>===
 +
click cmpID, event
 +
 
 +
cmpID: component ID or component name
 +
 
 +
event: 0 - release event; 1 - press event
 +
 
 +
*Example
 +
<pre>
 +
click b0, 1  //activate press event of component b0
 +
click 2, 0  //activate release event of component 2
 +
</pre>
 +
 
 +
Remark:
 +
 
 +
1, Use "click" command to activate press/release event of a component without touch the LCD.
 +
 
 +
===<font color="#007FFF">ref_stop: Stop refreshing screen</font>===
 +
 
 +
*Example
 +
<pre>ref_stop  // no parameters</pre>
 +
Remarks:
 +
 
 +
1.If you do not want to see the whole waveform flow progress, rather, you want to view the whole waveform all at once, you can stop refreshing the screen and refresh it when all adopted points being passed through.
 +
 
 +
2.Once stop refreshing the screen, all other commands and responded attribute assign operations will still run normally, but the components on the screen will not auto-refresh, neither will any changes in component attributes be refreshed and displayed on the screen(the changes are valid). When the device receive the command ref_star, those changes will be immediately refreshed and displayed on the screen (on condition that the changes are made from the attributes in green bold font).   
 +
 
 +
3.When stop refreshing the screen, ref command will still be executed. Besides, all GUI drawing instructions such as draw point, draw line will still be executed and any changes will be immediately displayed.
 +
----------------
 +
 
 +
===<font color="#007FFF">ref_star: Recover refreshing screen</font>===
 +
ref_star: recover refreshing screen
 +
*Example
 +
<pre>ref_star  // no parameters</pre>
 +
Remarks:
 +
 
 +
This command should be used after ref_stop command.
 +
----------------
 +
 
 +
===<font color="#007FFF">get: Get variable/constant value  with format</font>===
 +
get att
 +
 
 +
att: variable name
 +
 
 +
*Example 1
 
<pre>get t0.txt      //return t0's txt value</pre>
 
<pre>get t0.txt      //return t0's txt value</pre>
*Instance 2
+
*Example 2
 
<pre>get j0.val    //return J0's val value
 
<pre>get j0.val    //return J0's val value
 
</pre>
 
</pre>
 +
*Example 3
 +
<pre>get "123"      //return constant string "123"</pre>
 +
*Example 4
 +
<pre>get 123      //return constant value: 123</pre>
  
 
Remarks:  
 
Remarks:  
Line 44: Line 105:
 
1. When returned value is a string, the returned data is 0X70+ASCII code+0xff 0xff 0xff.  
 
1. When returned value is a string, the returned data is 0X70+ASCII code+0xff 0xff 0xff.  
  
2. When returned value is numerical data, returned data is 0X71+4 byte binary data+0xff 0xff 0xff. The data storage mode is little-endian mode (namely, low-order in front, and high-order at back).  
+
2. When returned value is numerical, returned data is 0X71+4 byte binary data+0xff 0xff 0xff. The data storage mode is little-endian mode (namely, low-order in front, and high-order at back).  
  
 
3. The specific returning format of data, please refer to the table: Format of Device Return Data  
 
3. The specific returning format of data, please refer to the table: Format of Device Return Data  
 
-------------------------
 
-------------------------
===<font color="#007FFF">sendme</font>===
+
 
*Instance:  
+
===<font color="#007FFF">sendme: send current pageID to UART</font>===
<pre>sendme  //No parameter
+
*Example:  
 +
<pre>sendme  //no parameters
 
</pre>
 
</pre>
  
 
Remarks:  
 
Remarks:  
  
Device will immediately send the current page ID to serial port after receiving this instruction.  
+
If you want the page auto-send pageID every refresh, simply enter sendme in page initialize event.
 +
-------------------------
 +
 
 +
===<font color="#007FFF">cov: variable type conversion</font>===
 +
 
 +
cov att1,att2,lenth
 +
 
 +
att1: source variable
 +
 
 +
att2: target variable
 +
 
 +
lenth: length of the string(0 - automatic length, nonzero - fixed length)
 +
 
 +
*Example 1:
 +
<pre>cov h0.val,t0.txt,0  //convert the value variable of slider h0 val into decimal string and assign the txt variable of t0, the length is automatic
 +
</pre>
 +
*Example 2:
 +
<pre>cov t0.txt,j0.val,0  //convert the string variable of t0 txt into value and assign the variable of slider h0 val, the length is automatic
 +
</pre>
 +
Remarks:
 +
 
 +
1.lenth always represents the length of the string, when the value converts into string, it is the length of target variable; when the string converts into value, it is the length of source variable.
 +
 
 +
2. If the target variable and source variable are of the same type, the conversion failed.
  
The specific sending format of data, please refer to the table: Format of Device Return Data.
 
 
-------------------------
 
-------------------------
  
===<font color="#007FFF">touch_j</font>===
+
===<font color="#007FFF">touch_j: Touch calibration</font>===
*Instance 1:  
+
touch_j:
 +
 
 +
*Example:  
 
<pre>touch_j  //Enter touch calibration function, this command does not need parameter
 
<pre>touch_j  //Enter touch calibration function, this command does not need parameter
 
</pre>
 
</pre>
 
Remarks:
 
Remarks:
 
   
 
   
All the devices have been calibrated, this command is not needed under normal circumstances
+
All the devices have been calibrated before packing from the factory, this command is not needed under normal circumstances
 
------------------------
 
------------------------
===<font color="#007FFF">cle_c</font>===
+
 
*Instance 1:  
+
 
<pre>cle_c //This command does not need parameter
+
===<font color="#007FFF">substr: Extracts the characters from a string</font>===
 +
 
 +
substr att0,att1,star,lenth
 +
 
 +
att0: A string from which a substring is to be returned
 +
 
 +
att1: Returned substring
 +
 
 +
star: The position where to start the extraction. First character is at index 0
 +
 
 +
lenth: Specifies the length of the returned string
 +
 
 +
 
 +
*Example:  
 +
<pre> substr t0.txt,t1.txt,0,2  
 +
</pre>
 +
Remarks:
 +
 +
All the devices have been calibrated before packing from the factory, this command is not needed under normal circumstances
 +
------------------------
 +
 
 +
===<font color="#007FFF">vis: Hide/show component</font>===
 +
 
 +
vis obj,state
 +
 
 +
obj: component name or component ID
 +
 
 +
*Example 1:
 +
<pre>vis b0,0  //hide component b0
 +
</pre>
 +
*Example 2:
 +
<pre>vis b0,1  //show component b0
 +
</pre>
 +
*Example 3:
 +
<pre>vis 1,0  //hide the component whose ID is 1
 +
</pre>
 +
*Example 4:
 +
<pre>vis 1,1  //show the component whose ID is 1
 
</pre>
 
</pre>
  
 
Remarks:  
 
Remarks:  
+
 
When you use this command, all touch areas you set in the current page will neither be valid, nor automatically be identified.Until you use the "page" command, the touch areas can be reloaded.
+
1.The first parameter 255 means all components in current page, for example: vis 255,0 (hide all components in current page); vis 255,1 (show all components in current page).
 +
 
 +
------------------------
 +
 
 +
===<font color="#007FFF">tsw: Enable/disable component touch function</font>===
 +
 
 +
tsw cmp,state
 +
 
 +
cmp: component name or component ID
 +
 
 +
state:(0=disable or 1=enable)
 +
 
 +
*Example 1:
 +
<pre>tsw b0,0  //component b0 touch invalid
 +
</pre>
 +
*Example 2:
 +
<pre>tsw b0,1  //component b0 touch valid
 +
</pre>
 +
*Example 3:
 +
<pre>tsw 1,0  //component of ID 1 touch invalid
 +
</pre>
 +
*Example 4:
 +
<pre>tsw 1,1  //component of ID 1 touch valid
 +
</pre>
 +
Remarks:
 +
 
 +
1.The first parameter 255 means all components in current page, for example: tsw 255, 0 (all components in current page touch invalid); tsw 255, 1 (all components in current page touch valid).
 +
 
 
--------------------
 
--------------------
===<font color="#007FFF">com_stop</font>===
+
 
*Instance 1:  
+
===<font color="#007FFF">com_stop: Stop execute instructions from UART </font>===
<pre>com_stop  //This instruction does not need parameter</pre>
+
*Example:  
 +
<pre>com_stop  //no parameters</pre>
  
 
Remarks:  
 
Remarks:  
Line 87: Line 238:
 
When using this command to pause the execution, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.
 
When using this command to pause the execution, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.
 
------------------
 
------------------
===<font color="#007FFF">com_star</font>===
+
 
*Instance 1:  
+
===<font color="#007FFF">com_star: Execute instructions from UART</font>===
<pre>com_star  //This instruction does not need parameter</pre>
+
*Example:  
 +
<pre>com_star  //no parameters</pre>
  
 
Remarks:  
 
Remarks:  
  
After receiving this command, the device will execute all the commands that store in the buffer.
+
After receiving this command, the device will execute all the commands that store in buffer and new commands form UART.
  
When using this command to recover the execution, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.
+
When using com_stop and com_start, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.
 
------------------
 
------------------
===<font color="#007FFF">code_c</font>===
 
Instance 1:
 
<pre>code _c  //This instruction does not need parameter</pre>
 
  
Clear the commands that is stored in the buffer but not executed.
+
===<font color="#007FFF">randset: Set random value range</font>===
 +
 
 +
 
 +
randset minval,maxval
 +
 
 +
minval: minimum value
 +
 
 +
maxval: maximum value
 +
 
 +
*Example:
 +
<pre>ranset 1,100  //set current value randomly generated from 1 to 100
 +
</pre>
 +
Remarks:
 +
 
 +
1. You should use randset to set random value generated range beforehand. Without setting randset, the value range will be 0~4294967295 by default. Aftering setting randset,  you will get a new random value within the preset range every time you run rand
 +
 
 +
2. The range set by randset keeps valid unless the device being reboot or reset.
 
------------------
 
------------------
===<font color="#007FFF">print</font>===
 
Let the device serial send user-defined strings
 
  
print str
+
===<font color="#007FFF">code_c: Clear the buffer</font>===
str: string content to be sent
+
*Example:  
*Instance: print abcd (let the device send the four bytes string abcd)
+
<pre>code_c  //no parameters</pre>
  
 
Remarks:
 
Remarks:
 +
Clear the commands that is stored in the buffer without execution.
 +
------------------
  
1.print and printh commands are executed only when the device is running, they will not be executed in the software simulator.
+
===<font color="#007FFF">print: Get variable variable/constant value  without format</font>===
  
2. When using the print command to send data, the device sends specified characters only, neither start character nor terminator can be sent.
+
 
 +
 
 +
print att
 +
 
 +
att: variable name
 +
 
 +
*Example 1:
 +
<pre>print t0.txt //returns the txt property value of component t0 in ASCII</pre>
 +
*Example 2:
 +
<pre>print j0.val //returns val’s property value of component j0 in 4-byte hexadecimal data</pre>
 +
*Example 3:
 +
<pre>print "123" //returns the ASCII of string "123":0x31 0x32 0x33</pre>
 +
*Example 4:
 +
<pre>print 123 //returns the 4-byte hexadecimal data of value "123":0x7B 0x00 0x00 0x00</pre>
 +
 
 +
Remarks:
 +
 
 +
1. When the variable obtained by using print command is string type, the device directly returns string ASCII; if it is numeric type (such as progress val property) , the device will directly return the variable’s 4-byte hexadecimal data, value is stored as little-endian mode (ie low level in the front, high level at the back ).
 +
 
 +
2. When use print command to obtain data, the device sends only the data content, no start identifier, nor end mark.
 +
 
 +
3.print command can match up printh command to add a piece of user-defined label in the front so as to tell the microcontroller which component this variable belongs to).
 +
 
 +
4. print command is very similar to get command, the only difference between them is get command returns data with initial identifier (0x70 or 0x71) and end mark (0xff 0xff 0xff), while print not.
 
------------------
 
------------------
  
===<font color="#007FFF">printh</font>===
+
===<font color="#007FFF">printh: Send hexadecimal string</font>===
Let the device serial send user-defined hexadecimal byte
+
  
 
printh hex
 
printh hex
hex: the characters'hexadecimal string expression to be sent
+
hex: the characters' hexadecimal string expression to be sent
Example: printh d0 a0 (let device send these two bytes 0xd0 0xa0)
+
 
 +
*Example  
 +
<pre>printh d0 a0 //let device send these two bytes 0xd0 0xa0</pre>
  
 
Remarks:
 
Remarks:
  
1. print and printh commands are executed only when the device is running, they will not be executed in the software simulator.
+
1. print and printh commands are executed only in Nextion display, they will not be shown in the software simulator.
  
2. When using printh command to send data, the device sends specified characters only, no start character, space and terminator can be sent.
+
2. When using printh command to send data, the device sends specified characters only, no Start character, Space character or End character.
 +
 
 +
3. There must have one and only Space separated between each set of characters in the parameter,  both upper case and lower case are supported in the hexadecimal string expression.
  
3. There must have one and only space separated between each set of characters in the parameter,  both upper case and lower case are supported in the hexadecimal string expression.
 
string expression
 
 
------------------
 
------------------
  
===<font color="#007FFF">add</font>===
+
===<font color="#007FFF">add: Add data to waveform component</font>===
Add data to Waveform component
+
  
 
add objid, ch, val
 
add objid, ch, val
objid: curve component ID number
+
 
ch: curve component channel number
+
objid: Waveform component ID
 +
 
 +
ch: Waveform component channel number
 +
 
 
val: value (maximum 255, minimum 0)
 
val: value (maximum 255, minimum 0)
*Instance 1: add 1,0,30 (add data 30 to curve component channel 0 of the curve component which ID number is 1)
+
 
*Instance 2: add 1,1,50 (add data 50 to curve component channel 1 of the curve component which ID number is 1)
+
*Example 1
 +
<pre>add 1, 0, 30 //add data 30 to channel 0 of the Waveform component which ID number is 1</pre>
 +
*Example 2
 +
<pre>add 1, 1, 50 //add data 50 to channel 1 of the Waveform component which ID number is 1</pre>
  
 
Remarks:
 
Remarks:
  
1.Each page supports up to four Waveform components, each Waveform component supports up to four channels. It can transmit data continuously, the component will automatically push.
+
1.Waveform component only support 8-bit values, 0 minimum, 255 maximum.  
  
Display data. in the process of sending data, control properties can be modified at any time, such as modify the foreground or background color of each channel.
+
2.Each page supports up to four Waveform components, each Waveform component supports up to four channels. It supports continuously pass through data, the component will auto-flow and display the value. It supports to change attributes during passing through data, such as change the background color or foreground color for each channel during the process.
 +
----------------
 +
 
 +
===<font color="#007FFF">addt: Add data to waveform component in volume</font>===
 +
 
 +
addt objid, ch, qty
 +
 
 +
objid: waveform component ID
 +
 
 +
ch: channel number of waveform component
 +
 
 +
qty: adopted point quantity of the data
 +
 
 +
*Example:
 +
<pre>addt 1, 0, 100  //waveform component whose ID is 1 enter into data pass through mode, pass through adopted point quantity is 100
 +
</pre>
 +
Remarks:
 +
 
 +
1.Waveform component only support 8-bit values, 0 minimum, 255 maximum. Single pass through is 1024 bits maximum.
 +
 
 +
2.After sending waveform data pass through command, it will take some time to get the device responded and started passing through values. This period takes about 5ms(it will take longer if there are other commands to be executed in the buffer zone before executing data pass through command). Following this period, it will send a data pass through ready data(0XFE+Terminator) to user, then it will start sending pass through data. The data being passed are only hexadecimal numbers. It recovers to command receiving state only after the device has adopted specified data.
 +
 
 +
3.Waveform will not refresh until specified data has been passed through completely.
 +
--------------
 +
 
 +
===<font color="#007FFF">cle: Clear data in waveform component</font>===
 +
 
 +
cle objid, ch
 +
 
 +
objid: waveform component ID (component name or variable is not supported);
 +
ch: channel
 +
 
 +
*Example:
 +
<pre>
 +
cle 1, 0  //clear the data of waveform component ID=1, channel=0;
 +
cle 1, 255  //clear all the data of waveform component ID=1 </pre>
 +
 
 +
Remarks:
 +
ch=255: all channels
 +
 
 +
===<font color="#007FFF">rest: Reset Nextion device</font>===
 +
 
 +
rest
 +
 
 +
Example:
 +
 
 +
<pre> rest    //no parameters  </pre>
 +
------------------
 +
===<font color="#007FFF">doevents: Force refresh the screen immediately</font>===
 +
 
 +
doevents
 +
 
 +
Example:
 +
 
 +
<pre> doevents //no parameters
 +
 
 +
while(n0.val<1024)
 +
{
 +
n0.val++
 +
doevents    //the screen will keep refreshing during the loop
 +
}
 +
</pre>
 +
 
 +
Remark:
 +
1, In a long looping statement, you can use doevents to avoid the screen display like brick.
 +
2, doevents usually work with "while" or "for" statement.
 +
 
 +
===<font color="#007FFF">strlen: check length of a string</font>===
 +
strlen att0, att1
 +
 
 +
att0: source string variable
 +
att1: return value, length of att0
 +
 
 +
Example:
 +
 
 +
<pre> strlen t0.txt, n0.val  //assign length of t0.txt to n0.val</pre>
 +
 
 +
Remark:
 +
 
 +
1, att0 must be string, att1 must be numeric.
 +
------------------
 +
 
 +
===<font color="#007FFF">if: if statement</font>===
 +
*Example 1: If to.txt equals to 123456, it will switch to page 1
 +
 
 +
<pre>if(t0.txt==”123456”)
 +
{   
 +
Page 1
 +
}
 +
</pre>
 +
 
 +
*Example 2: Below codes can switch content of txt of button component b0 between start and stop in press event)
 +
<pre>if(b0.txt==”start”
 +
{   
 +
  b0.txt==”stop” 
 +
} else
 +
{
 +
  b0.txt==”start” 
 +
}
 +
</pre>
 +
 
 +
*Example 3: Below codes can switch content of txt of button component b0 among 1, 2, 3 in press event)
 +
<pre>if(b0.txt==”1”
 +
{   
 +
  b0.txt==”2” 
 +
} else if (b0.txt==”2” )
 +
{
 +
  b0.txt==”3” 
 +
}else
 +
{
 +
  b0.txt==”1”
 +
}
 +
</pre>
 +
 
 +
Remarks:
 +
 
 +
1. Numerical variable supports operators: “>, <, ==, !=, >=, <=”
 +
 
 +
2. Character and String variable supports operators: “==, !=”
 +
 
 +
3. Nested “()” operator is not allowed. It does not support comparison operation, such as: if (j0.val + 1> 0).
 +
 
 +
4. Operator “()” must be paired.
 +
 
 +
5. Supports nested “if” and “else if” statement.
 +
 
 +
6.Complex expression, such as “if (j0.val+1>0)” is not supported
 +
 
 +
7.Download "if" HMI demo here: [http://support.iteadstudio.com/helpdesk/attachments/1029054663 Demo]
 +
 
 +
===<font color="#007FFF">while: while statemet</font>===
 +
 
 +
Example:
 +
<pre>
 +
 
 +
//n0.val will auto-add to 100, in this process the screen will
 +
//not refresh the result until all the statements of this process
 +
//being completely executed.
 +
while(n0.val<100)
 +
{
 +
n0.val++
 +
}
 +
 
 +
 
 +
//n0.val will auto-add to 100, in this process the screen will
 +
//keep refreshing and displaying the result of component n0.
 +
 
 +
while(n0.val<100)
 +
{
 +
n0.val++
 +
doevents
 +
}  </pre>
 +
 
 +
Remarks:
 +
1, In the process of executing a while loop, the device will not show corresponding touch event, serial command will be received in buffer, but not executed until all the statements in the process has finished execution. Please be cautious when using this command, or it might be easily enter into endless loop.
 +
2, It's recommended to use "doevents" command together.
 +
3, refer to remark of "if" statement
 +
 
 +
===<font color="#007FFF">for: for statemet</font>===
 +
 
 +
*Examples:
 +
<pre>
 +
 
 +
//n0.val will auto-add to 100, in this process the screen will
 +
//not refresh the result until all the statements of this process
 +
//being completely executed.
 +
 
 +
for(n0.val=0; n0.val<100; n0.val++)
 +
{
 +
}
 +
 
 +
//n0.val will auto-add to 100, in this process the screen will
 +
// keep refreshing and displaying the result of component n0 .
 +
 
 +
for(n0.val=0; n0.val<100; n0.val++)
 +
{
 +
doevents 
 +
}
 +
 
 +
</pre>
 +
 
 +
===<font color="#007FFF">repo: read EEPROM - Enhanced Model Only </font>===
 +
 
 +
repo att, add
 +
 
 +
att: variable/constant
 +
 
 +
add: storage address in EEPROM
 +
 
 +
Example:
 +
 
 +
<pre>repo t0.txt,10 // read and assign value to t0.txt, read length is (t0.txt-mal)+1
 +
repo n0.val,10      //read and assign value to n0.val, read length is 4 bytes</pre>
 +
 
 +
Remark:
 +
 
 +
1, read a string from EEPROM, read length is length of the string+1.
 +
 
 +
2, read a numeric value from EEPROM, read length is 4 bytes.
 +
--------------
 +
 
 +
===<font color="#007FFF">wepo: write EEPROM - Enhanced Model Only </font>===
 +
 
 +
wepo att,add
 +
 
 +
att: variable/constant
 +
 
 +
add: storage address in EEPROM
 +
 
 +
Example:
 +
 
 +
<pre>wepo t0.txt,10 // write value of t0.txt to EEPROM, start from address #10. storage size is (t0.txt-mal)+1 bytes
 +
wepo "abcd",10  // write string "abcd" to EEPROM, start from address #10. storage size is 5 bytes
 +
wepo 11,10  //write constant 11 to EEPROM, start from address #10. storage size 4 bytes  </pre>
 +
 
 +
Remark:
 +
 
 +
1, Storage address start from 0byte to 1023byte.
 +
 
 +
2, Storage size of a string is 1 byte + string length; storage size of a numeric constant is 4 bytes.
 +
 
 +
3, Supported numeric data type is long integer, from -2,147,483,648 to 2,147,483,647    [v035 supports 0 to 2,147,483,647 only]
 +
----------------
 +
 
 +
===<font color="#007FFF">wept: write data in hex to EEPROM through UART - Enhanced Model Only </font>===
 +
 
 +
wept add, length
 +
 
 +
add: start address in EEPROM
 +
 
 +
length: length of data
 +
 
 +
 
 +
Example:
 +
 
 +
<pre>wept 30, 20 // write 20 bytes of hex data from UART to EERPOM, start address is 30 </pre>
 +
 
 +
Remark:
 +
 
 +
1, When wept instruction received, Nextion device will take around 5ms to initiate and send ready signal “0xFE 0xFF 0xFF 0xFF"
 +
 
 +
2, Before you send data from UART, you should wait until you get ready signal from Nextion device
 +
 
 +
3, wept can not be terminated.
 +
----------
 +
 
 +
 
 +
===<font color="#007FFF">rept: read data in hex from EEPROM to UART - Enhanced Model Only </font>===
 +
 
 +
rept add, lenght
 +
 
 +
add: start address in EEPROM
 +
 
 +
length: length of data
 +
 
 +
Example:
 +
 
 +
<pre>rept 30, 20 // read 20 bytes of hex data from EEPROM to UART, start address is 30 </pre>
 +
--------
 +
 
 +
===<font color="#007FFF">cfgpio: configure GPIO - Enhanced Model Only </font>===
 +
 
 +
cfgpio id,state,cmp
 +
 
 +
id: I/O pin number
 +
 
 +
state:  work state of the GPIO
 +
  0 - pull up input mode
 +
  1 - input binding mode
 +
  2 - push pull output mode
 +
  3 - PWM output mode
 +
  4 - open drain output mode
 +
 
 +
cmp: binding component, available in work state 2
 +
 
 +
Example:
 +
 
 +
<pre>cfgpio 0, 0, 0    //Configure GPIO0 as pull up input mode, you can read the input status from system variable pio0,
 +
                      //such as: n0.val = pio0
 +
 
 +
cfgpio 1, 2, 0  //Configure GPIO1 as push pull output mode, you can control the output level
 +
                //by system variable pio1, such as: pio1 = 1
 +
 
 +
cfgpio 2, 1, b0  //Configure GPIO2 as input binding mode, the binding component is button b0.
 +
                  //Falling edge of GPIO2 will trigger b0's button press event, rising edge of
 +
                  //GPIO2 will trigger bo's button release event.
 +
 
 +
cfgpio 4, 3, 0  //Configure GPIO4 as PWM output mode, you should use system variable pwm4
 +
                //to set duty cycle before you use the instruction
 +
</pre>
 +
 
 +
Remark:
 +
 
 +
1, only GPIO4 to GPIO7 support PWM function
 +
 
 +
2, When configure a GPIO to input binding mode, only components in current page can be bind. It is recommended to put the instruction in the preinitialize event, because binding event wont not be triggered after page refreshing or switching.
 +
-------
  
 
=='''Classification II:  GUI Designing Command'''==
 
=='''Classification II:  GUI Designing Command'''==
 
Note: When you can’t realize some special GUI designing in Nextion Editor, you can use some GUI commands to make it happen. Generally, the controls in Nextion editor can satisfy your GUI designing demand.
 
Note: When you can’t realize some special GUI designing in Nextion Editor, you can use some GUI commands to make it happen. Generally, the controls in Nextion editor can satisfy your GUI designing demand.
  
===<font color="#007FFF">cls color</font>===
+
===<font color="#007FFF">cls: clear the screen</font>===
 +
cls color
 +
 
 
color: Decimal color value or color code
 
color: Decimal color value or color code
  
*Instance 1:  
+
*Example 1:  
 
<pre>cls 1024  //Refresh the screen with decimal 1024 color value</pre>
 
<pre>cls 1024  //Refresh the screen with decimal 1024 color value</pre>
*Instance 2:  
+
*Example 2:  
 
<pre>cls RED  //Refresh the screen with the color of code RED (RED represents red color)</pre>
 
<pre>cls RED  //Refresh the screen with the color of code RED (RED represents red color)</pre>
  
 
Both Decimal color value and Color code are supported in Nextion Editor
 
Both Decimal color value and Color code are supported in Nextion Editor
 
----------------------
 
----------------------
===<font color="#007FFF">pic x,y,picid</font>===
+
 
 +
===<font color="#007FFF">pic: display picutres</font>===
 +
 
 +
pic  x, y, picid
  
 
x: x coordinate starting point;  
 
x: x coordinate starting point;  
Line 171: Line 666:
 
picid: Picture ID;  
 
picid: Picture ID;  
  
*Instance 1:  
+
*Example 1:  
<pre>pic 10,20,0  //Display the picture (ID is 0) in resource file at the coordinate (10,20)</pre>
+
<pre>pic 10, 20, 0  //Display the picture (ID is 0) in resource file at the coordinate (10, 20)</pre>
*Instance 2:  
+
*Example 2:  
<pre>pic 40,50,1  //Display the picture (ID is 1) in resource file at the coordinate (40,50)</pre>
+
<pre>pic 40, 50, 1  //Display the picture (ID is 1) in resource file at the coordinate (40, 50)</pre>
 
---------------------
 
---------------------
===<font color="#007FFF">picq x,y,w,h,picid</font>===
+
 
 +
===<font color="#007FFF">picq: Crop picture</font>===
 +
 
 +
picq x, y, w, h, picid
  
 
x: x coordinate starting point;  
 
x: x coordinate starting point;  
Line 182: Line 680:
 
y: y coordinate starting point;
 
y: y coordinate starting point;
 
   
 
   
w: Region width;  
+
w: area width;  
  
h: Region height;  
+
h: area height;  
  
 
picid: Picture ID;  
 
picid: Picture ID;  
  
*Instance 1:  
+
*Example:  
<pre>picq 20,50,30,20,0  //Crop the area from starting coordinate (20,50) , with a width 30×height 20 size, in the picture 0 (the background picture must be full-screen) and display it on the screen, and the display coordinate is the starting coordinate (20,50).</pre>
+
<pre>picq 20, 50, 30, 20, 0   
 +
//Crop the area from starting coordinate (20, 50) , with a width 30×height 20 size,  
 +
//in the picture 0 (the background picture must be full-screen) and display it on  
 +
//the screen, and the display coordinate is the starting coordinate (20, 50).</pre>
  
 
Remarks:  
 
Remarks:  
Line 195: Line 696:
 
This instruction requires that the background picture must be full-screen; otherwise, the image you crop is not the one you want. The crop image area and the display area is overlap on the screen.  
 
This instruction requires that the background picture must be full-screen; otherwise, the image you crop is not the one you want. The crop image area and the display area is overlap on the screen.  
 
-----------------------
 
-----------------------
===<font color="#007FFF">xstr x,y,w,h,fontid,fontcolor,backcolor,xcenter,ycenter,sta,string</font>===
+
 
 +
===<font color="#007FFF">xpic: Advanced crop picture</font>===
 +
 
 +
xpic x, y, w, h, x0, y0, picid
 +
 
 +
x: x coordinate starting point;
 +
 
 +
y: y coordinate starting point;
 +
 +
w: Region width;
 +
 
 +
h: Region height;
 +
 
 +
x0: crop picture starting point x coordinate;
 +
 
 +
y0: crop picture starting point y coordinate;
 +
 
 +
picid: Picture ID;
 +
 
 +
 
 +
*Example:
 +
<pre>picq 20, 50, 30, 20, 15, 15, 0 
 +
//Crop the area from starting coordinate (15, 15) ,
 +
//with a width 30 × height 20 size, in the picture 0 (the background
 +
//picture must be full-screen) and display it on the screen, and the display
 +
//coordinate is the starting coordinate (20, 50).</pre>
 +
 
 +
 
 +
 
 +
 
 +
--------------
 +
 
 +
===<font color="#007FFF">xstr: Print string on the device</font>===
 +
xstr x, y, w, h, fontid, fontcolor, backcolor, xcenter, ycenter, sta, string
  
 
x: x coordinate starting point;
 
x: x coordinate starting point;
Line 201: Line 735:
 
y: y coordinate starting point;  
 
y: y coordinate starting point;  
  
w: Region width;  
+
w: area width;  
  
h: Region height;  
+
h: area height;  
  
 
fontid: Font ID;  
 
fontid: Font ID;  
Line 215: Line 749:
 
ycenter: Vertical alignment (0 is upper-aligned, 1 is centered, 2 is lower-aligned);  
 
ycenter: Vertical alignment (0 is upper-aligned, 1 is centered, 2 is lower-aligned);  
  
sta: Background fill(0-crop image;1-solid color;2-Image, when set sta as Crop Image or Image, backcolor means image ID);
+
sta: Background fill(0-crop image;1-solid color;2-Image; 3-No backcolor, when set sta as Crop Image or Image, backcolor means image ID);
  
 
string: Character content;  
 
string: Character content;  
  
*Instance 1:  
+
*Example:  
<pre>xstr 0,0,100,30,1,RED,BLACK,1,1,1, China</pre>
+
<pre>xstr 0, 0, 100, 30, 1, RED, BLACK, 1, 1, 1, "China"</pre>
 
*Explanation:  
 
*Explanation:  
Use font 1, at the starting point coordinate(0,0), write"China" in an area that its width is 100, height is 30, the font color is RED, background color is BLACK(if you do not want any background color, use NULL), horizontal alignment is center, and vertical alignment is center too.
+
Use font 1, at the starting point coordinate(0,0), write"China" in an area that its width is 100, height is 30, the font color is RED, background color is BLACK, horizontal alignment is center, and vertical alignment is center too.
  
  
 
Remarks:
 
Remarks:
 
   
 
   
1.There is automatic word wrapping if characters exceeds the default set w. If there are remaining characters not written out when wrapped to h, they will be neglected.  
+
1.There is automatic word wrapping if characters exceeds the default set w. If there are remaining characters not written out when wrapped to h, they will be neglected.  
  
 
2. For more information about color value, please refer to cls command.   
 
2. For more information about color value, please refer to cls command.   
 
-------------------
 
-------------------
  
===<font color="#007FFF">fill x,y,w,h,color</font>===
+
===<font color="#007FFF">fill x, y, w, h, color</font>===
 +
Fill area
 +
 
 
x: x coordinate starting point;  
 
x: x coordinate starting point;  
  
 
y: y coordinate starting point;  
 
y: y coordinate starting point;  
  
w: Region width;  
+
w: area width;  
  
h: Region height;  
+
h: area height;  
  
color: Fill color;  
+
color: fill color;  
  
*Instance 1:  
+
*Example:  
<pre>fill 0,0,100,30,RED  //Fill color RED in the area of starting coordinate (0,0) and width 100×height 30
+
<pre>fill 0, 0, 100, 30, RED  //Fill color RED in the area of starting coordinate (0, 0) and width 100×height 30
 
</pre>
 
</pre>
  
Line 251: Line 787:
 
For more information about color value, please refer to cls command.
 
For more information about color value, please refer to cls command.
 
--------------
 
--------------
===<font color="#007FFF">line x,y,x2,y2,color</font>===
+
 
 +
===<font color="#007FFF">line x, y, x2, y2, color</font>===
  
 
x: x coordinate starting point;
 
x: x coordinate starting point;
Line 263: Line 800:
 
color: Line color;
 
color: Line color;
 
   
 
   
*Instance 1:  
+
*Example:  
<pre>line 0,0,100,100,RED  //Draw a line in color RED between the coordinate (0,0) and the coordinate (100,100)
+
<pre>line 0, 0, 100, 100, RED  //Draw a line in color RED between the coordinate (0, 0) and the coordinate (100, 100)
 
</pre>
 
</pre>
  
Line 271: Line 808:
 
For more information about color value, please refer to cls command.
 
For more information about color value, please refer to cls command.
 
---------------
 
---------------
===<font color="#007FFF">draw x,y,x2,y2,color</font>===
 
x: x coordinate of starting point;
 
  
y: y coordinate of starting point;
+
===<font color="#007FFF">draw x, y, x2, y2, color</font>===
 +
x: x coordinate starting point;
 +
 
 +
y: y coordinate starting point;
 
   
 
   
x2: x coordinate of ending point;  
+
x2: x coordinate ending point;  
  
y2: y coordinate of ending point;  
+
y2: y coordinate ending point;  
  
 
color: Line color;
 
color: Line color;
 
   
 
   
*Instance 1:  
+
*Example:  
<pre>draw 0,0,100,100,RED    //Draw a rectangle, the top left coordinate is (0,0) and bottom right corner is (100,100), rectangle frame color is RED.</pre>
+
<pre>draw 0, 0, 100, 100, RED    //Draw a rectangle, the top left coordinate is (0, 0) and bottom right corner is (100, 100), rectangle frame color is RED.</pre>
  
 
Remarks:  
 
Remarks:  
Line 290: Line 828:
 
2. For more information about color value, please refer to cls command.
 
2. For more information about color value, please refer to cls command.
 
-------------------
 
-------------------
===<font color="#007FFF">cir x,y,r,color</font>===
+
 
 +
===<font color="#007FFF">cir x, y, r, color</font>===
 +
cir x, y, r, color: draw a hollow circle
  
 
x: Coordinate x of the center of a circle
 
x: Coordinate x of the center of a circle
Line 300: Line 840:
 
color: Line color;  
 
color: Line color;  
  
*Instance 1:  
+
*Example:  
<pre>cir 100,100,30,RED    //Draw a hollow circle of radius of 30 with the coordinate (100,100) as the center of a circle, circle frame line is RED</pre>
+
<pre>cir 100, 100, 30, RED    //Draw a hollow circle whose radius is 30 with the coordinate (100, 100) as the center of a circle, circle frame line is RED</pre>
  
 
Remarks:   
 
Remarks:   
Line 307: Line 847:
 
----------------
 
----------------
 
'''Nextion Editor supports decimal color value and color code using in all GUI designing commands, for more information, please refer to Color Code List.'''
 
'''Nextion Editor supports decimal color value and color code using in all GUI designing commands, for more information, please refer to Color Code List.'''
 +
 +
===<font color="#007FFF">cirs x, y, r, color</font>===
 +
cirs x, y, r, color:draw a solid circle
 +
 +
x: circle center x coordinate
 +
 +
y: circle center y coordinate
 +
 +
r: Radius
 +
 +
color: Fill color;
 +
*Example
 +
<pre>cirs 100, 100, 30, RED    //Draw a solid circle whose radius is 30 with the coordinate (100, 100) as the center of a circle, circle color is RED</pre>
 +
 +
Remarks: 
 +
For more information about color value, please refer to cls command.
 +
----------------
  
 
=='''Nextion HMI: System Variables List'''==
 
=='''Nextion HMI: System Variables List'''==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| align="center" style="background:#f0f0f0;"|'''Serial Number'''
+
| align="center" style="background:#f0f0f0;"|'''Item'''
 
| align="center" style="background:#f0f0f0;"|'''Name'''
 
| align="center" style="background:#f0f0f0;"|'''Name'''
 
| align="center" style="background:#f0f0f0;"|'''Meaning'''
 
| align="center" style="background:#f0f0f0;"|'''Meaning'''
 
| align="center" style="background:#f0f0f0;"|'''Instance/Remarks'''
 
| align="center" style="background:#f0f0f0;"|'''Instance/Remarks'''
 
|-
 
|-
| 1||dim||Current value of backlight b1ightness||1.dim=50  2.dim=dim+l0    3.dim=dim-l0  
+
| 1||dim||Current value of backlight brightness||1.dim=50  2.dim=dim+l0    3.dim=dim-l0  
When you set dim=80, it means you set the brightness to 80,but doesn’t save the data. Next time you power the the Nextion TFT, the brightness of backlight will keep its default setting.
+
When you set dim=80, it means you have set the brightness as 80, but did not save it as default. Next time you power on the Nextion TFT, the brightness of backlight will keep its default setting.
 
|-
 
|-
| 2||dims||default backlight brightness when Nextion power on||1.dims=50  2.dims=dims+10  3.dims=dims-l0  
+
| 2||dims||default backlight brightness when Nextion is powered on||1.dims=50  2.dims=dims+10  3.dims=dims-l0  
When you set dim=80 to Nextion TFT, it means you set the brightness to 80, and save the data as default. Next time you power the Nextion TFT, the brightness of backlight will be 80 by default.
+
When you set dims=80 to Nextion TFT, it means you have set the brightness as 80, and have saved it as default. Next time you power on the Nextion TFT, the brightness of backlight will be 80 by default.
 
|-
 
|-
 
| 3||baud||Current value of baud||1.baud=2400    2.baud=4800  3.baud=9600
 
| 3||baud||Current value of baud||1.baud=2400    2.baud=4800  3.baud=9600
Line 326: Line 883:
 
7.baud=115200
 
7.baud=115200
 
|-
 
|-
| 4||bauds||Default value of baud when Nextion power on||1.bauds=9600 is the default value of baud from factory.
+
| 4||bauds||Default value of baud when Nextion is powered on||1.bauds=9600 is the default baud of factory settings.
  
2.when you set bauds=115200 to Nextion, it means you set the baud to115200, and save the data as default. Next time you power the Nextion, the value of baud will be 115200 by detault.
+
2.when you set bauds=115200 to Nextion, it means you have set the baud as 115200, and saved it as default. Next time you power the Nextion, the value of baud will be 115200 by default.
 
|-
 
|-
| 5||spax||Hori spacing of font display  
+
| 5||spax||Horizontal spacing of font display  
(Powered default is 0)
+
(default 0)
 
||spax=2
 
||spax=2
 
|-
 
|-
 
| 6||spay||Vertical spacing of font display  
 
| 6||spay||Vertical spacing of font display  
(Powered default is 0)
+
(default 0)
 
||spay=2
 
||spay=2
 
|-
 
|-
| 7||thc||Brush color at touch drawing||l.the=RED 2.thc=l024
+
| 7||thc||Brush color at touch drawing||l.thc=RED 2.thc=l024
 +
|-
 +
| 8||thdra||Touch drawing function||thdra=0(C1ose) thdra=1(Open)
 +
|-
 +
| 9||ussp||If no serial data, it will auto activate sleep time (unit: second, minimum 3, maximum 65,535,  power-on default 0)||ussp=30(No serial data within 30 seconds, it auto will enter into sleep mode)
 +
ussp=0(invalid)
 +
|-
 +
| 10||thsp||If no touch operation, it will auto enter into sleep time (unit: second, minimum 3, maximum 65,535, power-on default 0)||thsp=30(No touch operation within 30 seconds, it will auto enter into sleep mode)
 +
thsp=0(invalid)
 
|-
 
|-
| 8||thdra||Switch of touch drawing function||thdra=0(C1ose) thdra=1(Open)
+
| 11||thup||Touch in sleep mode will auto-awake switch (power-on default 0)||thup=0(Touch will not auto awake switch during sleep mode)
 +
thup=1(Touch will autom awake switch during sleep mode)
 +
Remarks: Whether thup be 0 or 1, whenever there is any touch operation in sleep mode, the device will send touch coordinates to the serial port.
 
|-
 
|-
| 9||sendxy||Switch of real-time sending function of touch coordinate||sendxy=0(C1ose)  sendxy=0(Open)  
+
| 12||sendxy||Close or open real-time sending touch coordinate function ||sendxy=0(C1ose)  sendxy=1(Open)  
 
Remarks:
 
Remarks:
  
1. When sending function is open, the device will send touch coordinate through serial port when you touch the screen.
+
1. When this function is open, the device will send touch coordinate through serial port when you touch the screen.
2. Please refer to the table: Format of Device Return Data to know more about the format of sending the coordinate.
+
2. Please refer to the table: Format of Device Return Data to learn more about the format of sending the coordinate.
 
|-
 
|-
| 10||delay||||Delay=100(Pause the device for l00ms)
+
| 13||delay||||Delay=100(Pause the device for l00ms)
 
Remarks:
 
Remarks:
When delay command is executed, the CPU of the device will not execute any command, but will continue receiving serial port command and store them into buffer.
+
When delay command is executed, the CPU of the device will not execute any commands, but will continue receiving serial port command and store them to buffer.
 
|-
 
|-
| 11||sleep||||sleep=0 (Exit Sleep)  
+
| 14||sleep||||sleep=0 (Exit Sleep)  
 
sleep=l (Enter Sleep)
 
sleep=l (Enter Sleep)
  
 
Remarks:
 
Remarks:
  
When the device is enabled from sleep mode, the device will automatically re-fresh the current page, and the backlight brightness will recover to the default brightness value.
+
When the device wake up from sleep mode, the device will auto refresh the current page, and the backlight brightness will recover to the default brightness value.
 
Two commands available for changing the brightness of backlight, dim and dims.
 
Two commands available for changing the brightness of backlight, dim and dims.
 
|-
 
|-
| 12||bkcmd||Set serial command successful execution or fail execution data return(Default is 0)||bkcmd=0 (No return)  
+
| 15||bkcmd||Data return of successful/failed execute serial command(2 by default)||bkcmd=0 (No return)  
bkcmd=l (Only return the successful result)
+
bkcmd=l (Only return the successful data)
  
bkcmd=2(Only return the failed result)
+
bkcmd=2(Only return the failed data)
  
 
bkcmd=3(Always return)
 
bkcmd=3(Always return)
Line 369: Line 936:
 
Remarks:
 
Remarks:
  
This setting only affects the serial command’s successful execution or fail execution’s data return. In Nextion Editor’s editing interface, when there is a command execution error, it will return error data; when the command executes successfully, it will not return execution result data. This setting does not affect the data return of device control data acquisition.
+
This setting only affects the serial command’s successful execution or fail execution’s data return. In Nextion Editor’s editing interface, when there is a command execution error, it will return error data; when the command being executed successfully, it will not return execution result data.
 +
|-
 +
| 16||rand||random value
 +
||dim=rand (assign a random value to backlight brightness)
 +
 
 +
n0.val=rand (assign a random value to variable of n0.val)
 +
 
 +
Remarks:
 +
 
 +
1.Before use rand, you should use randset command to set random value generated range. If you do not set it, the default range will be 0~4294967295. Aftering setting randset,  you will get a new random value within the preset range every time you run rand.
 +
 
 +
2. The range set by randset keeps valid unless the device being reboot or reset.
 +
|-
 +
| 17||sys0
 +
sys1
 +
 
 +
sys2
 +
||Numeric system variables
 +
||sys0=10    sys1=40  sys2=60  n.val=sys2
 +
 
 +
Remarks:
 +
 
 +
ys0, sys1, sys2 are global variables, which do not required to define or create. You can use them in any page. Default value for these three variables are 0, they can be read and write, their value range are 0~4294967295. It's recommended to pass values through pages with they system variables.
 +
|-
 +
| 18||rtc0 to rtc6||RTC variables (Enhanced Only)|| rtc0, year; 
 +
 
 +
rtc1, month; 
 +
 
 +
rtc2, day; 
 +
 
 +
rtc3, hour; 
 +
 
 +
rtc4, min; 
 +
 
 +
rtc5, second;
 +
 
 +
rtc6, week;
 +
 
 +
|-
 +
| 19||pio0 to pio7||GPIO variables (Enhanced Only)||Default mode when power on: pull up input mode
 +
 
 +
Internal pull up resistor: 50K
 +
|-
 +
| 20||pwm4 to pwm7||Duty cycle for the PWM GPIO (Enhanced Only)|| min value = 0, max value = 100, default = 50;
 +
 
 +
|-
 +
| 21||pwmf||PWM frequency (Enhanced Only)||min value = 1Hz, max value = 65536 Hz, default = 1000Hz; 
 +
 
 +
All PWM output is unified to one frequency, no independent setting is allowed.
 +
 
 +
|-
 +
| 22||wup||Refresh certain page when wake up||wup=255 (default, refresh current page), wup=2 (refresh page 2 when wake up)
 +
 
 +
Note: Nextion can execute wup even in sleep mode; 
 +
 
 +
 
 
|}
 
|}
  
Line 397: Line 1,019:
  
 
=='''Format of Device Return Data'''==
 
=='''Format of Device Return Data'''==
 +
'''Table 1: serial l instruction execution success or failure notification format'''
 +
 +
1.Only when the system variable bkcmd is not zero will return instruction execution succeed or fail data, bkcmd defaults to 0 after each power on, which means it does not return the result of instruction execution.
 +
 +
2.The code of the source file is not affected by bkcmd when software is under editing, the error data will be returned when there is an execution error, and the error data will not be returned when execute success.
  
*'''Note: The returned data is end with three bytes of “0XFF 0XFF 0XFF”.'''
+
3.The returned data is ended with three bytes of “0XFF 0XFF 0XFF”.'''
  
 
{| class="wikitable"
 
{| class="wikitable"
| align="center" style="background:#f0f0f0;"|'''The first bit of return data'''
+
| align="center" style="background:#f0f0f0;"|'''The first byte of returned data'''
 
| align="center" style="background:#f0f0f0;"|'''Meaning'''
 
| align="center" style="background:#f0f0f0;"|'''Meaning'''
 
| align="center" style="background:#f0f0f0;"|'''Format'''
 
| align="center" style="background:#f0f0f0;"|'''Format'''
Line 416: Line 1,043:
 
|-
 
|-
 
|Return this data when the instruction sent by the user is successfully executed
 
|Return this data when the instruction sent by the user is successfully executed
 +
|-
 +
| rowspan=2 align="center"|0X02
 +
|rowspan=2|Component ID invalid
 +
|0X02+End
 +
|-
 +
|Return this data when the instruction from external device contains invalid component ID or invalid component name
 
|-
 
|-
 
| rowspan=2 align="center"|0X03
 
| rowspan=2 align="center"|0X03
Line 421: Line 1,054:
 
|0X03+End
 
|0X03+End
 
|-
 
|-
|Return this data when the instruction sent by the user contains invalid page ID or invalid page name
+
|Return this data when the instruction sent by external device contains invalid page ID or invalid page name
 
|-
 
|-
 
| rowspan=2 align="center"|0X04
 
| rowspan=2 align="center"|0X04
Line 434: Line 1,067:
 
|-
 
|-
 
|Return this data when the instruction sent by the user contains invalid font ID
 
|Return this data when the instruction sent by the user contains invalid font ID
 +
|-
 +
| rowspan=3 align="center"|0X11
 +
|rowspan=3|Baud rate setting invalid
 +
|0X11+End
 +
|-
 +
|The baud rate setting instruction sent by the user contains invalid baud rate parameter
 +
|-
 +
|Baud rate supported by the device including:2400 4800 9600 19200 38400 57600 115200
 +
|-
 +
| rowspan=2 align="center"|0X12
 +
|rowspan=2|Curve control ID number or channel number is invalid
 +
|0X12+End
 +
|-
 +
|When users use the add commands to add data to curve, this data will be returned as curve control ID number or channel number is invalid
 
|-
 
|-
 
|rowspan=3 align="center"| 0X1A
 
|rowspan=3 align="center"| 0X1A
Line 450: Line 1,097:
 
|-
 
|-
 
|For another example, the val attribute of progress bar j0 should be numerical, so it should be written as j0.val=50; it will be wrong if you write j0.val=“50” or j0.val=abc.  
 
|For another example, the val attribute of progress bar j0 should be numerical, so it should be written as j0.val=50; it will be wrong if you write j0.val=“50” or j0.val=abc.  
 +
|-
 +
|align="center"| 0X1C ||Failed to assign ||0X1C+End
 +
Return this data when attribute failed to assign.
 +
|-
 +
|align="center"| 0X1D ||Operate EEPROM failed ||0X1D+End
 +
Return this data when operate EEPROM failed.
 +
|-
 +
|align="center"| 0X1E ||Parameter quantity invalid ||0X1E+End
 +
Return this data when the instruction parameter quantity input by user is wrong.
 +
|-
 +
|align="center"| 0X1F ||IO operation failed ||0X1F+End
 +
Return this data when operate IO failed.
 +
|-
 +
|align="center"| 0X20 ||Undefined escape characters ||0X20+End
 +
Return this data when you use a undefined escape character.
 +
|-
 +
|align="center"| 0X23 ||Too long variable name ||0X23+End
 +
Maximum allowed length of a variable is 29 characters.
 +
|-
 +
|}
 +
 +
'''Table 2: other data return format'''
 +
 +
1.The returned data is end with three bytes of “0XFF 0XFF 0XFF”.
 +
 +
2.The following data’s return does not be affected by bkcmd.
 +
{| class="wikitable"
 +
| align="center" style="background:#f0f0f0;"|'''The first byte of returned data'''
 +
| align="center" style="background:#f0f0f0;"|'''Meaning'''
 +
| align="center" style="background:#f0f0f0;"|'''Format'''
 
|-
 
|-
 
|rowspan=5 align="center"| 0X65
 
|rowspan=5 align="center"| 0X65
Line 507: Line 1,184:
 
|Meaning: Return the string data: “abc”
 
|Meaning: Return the string data: “abc”
 
|-
 
|-
|rowspan=4 align="center"| 0X71
+
|rowspan=4 align="center"|0X71
|rowspan=4|Numerical variable data returns
+
|rowspan=4|Numeric variable data returns
|0X71+Variable Binary Data (4-byte is Little-endian Mode, low-order front)+End
+
|0X71+variable binary data(4 bytes little endian mode, low in front)+End
 
|-
 
|-
|When the variable obtained by get instruction is numerical, return to the data
+
|When the variable obtained by get command is value, this data returns.
 
|-
 
|-
|'''Instance: 0X71 0X66 0X00 0X00 0X00 0XFF 0XFF 0XFF'''
+
|'''Instance:0X71 0X66 0X00 0X00 0X00 0XFF 0XFF 0XFF'''
 
|-
 
|-
|Meaning: Return to numerical data: 102
+
|Meaning:return value data:102
 +
|-
 +
|-
 +
|align="center"|0X86|| Device automatically enters into sleep mode||0X86+End
 +
Only when the device automatically enters into sleep mode will return this data. If execute serial command “sleep = 1” to enter into sleep mode, it will not return this data.
 +
|-
 +
|align="center"|0X87|| Device automatically wake up||0X87+End
 +
Only when the device automatically wake up will return this data. If execute serial command “sleep=0” to wake up, it will not return this data.
 +
|-
 +
|align="center"|0X88|| System successful start up||This data is sent after a successful power-on initialization on the device
 +
|-
 +
|align="center"|0X89||Start SD card upgrade||This data is sent after the device power on and detect SD card, and then enter upgrade interface
 +
|-
 +
|align="center"|0XFD||Data transparent transmit finished||0xFD+End
 
|-  
 
|-  
 +
|align="center"|OXFE||Data transparent transmit ready ||The device will enter into transparent transmission data initialization mode after receiving data transparent transmission instruction. Data will be sent once the initialization is completed, which means it has entered into data transparent transmission mode and start to transparent transmit data.
 
|}
 
|}
  
 +
==Useful link==
 
<font color="#FF0000">'''Discuss Nextion here:'''</font>
 
<font color="#FF0000">'''Discuss Nextion here:'''</font>
 
<font color="#FF0000">'''http://support.iteadstudio.com/discussions/1000058038'''</font>
 
<font color="#FF0000">'''http://support.iteadstudio.com/discussions/1000058038'''</font>

Latest revision as of 08:41, 31 March 2017

Contents

Note:

1. The instruction is end with three bytes "0xff 0xff 0xff"

2. All the instrucitons and parametners are in ASCII

3. All the instrucitons are in lowercase letters

Classification I: Operation Commands of Component and System

page: Refresh page

page pageid

pageid: Page ID or Page Name

  • Example 1:
page 0         //Refresh page 0
  • Example 2:
page main    //Refresh the page main

Remarks:

The device automatically refresh page 0 when power on.


ref: Refresh component

ref cmpID

cmpID: component ID or component name

  • Example
ref t0   //refresh component t0
ref 1    // refresh component 1

Remarks:

1. The default loading mode is automatically load when you create and edit a component in Nextion Editor. If set it as manually load, you should use ref command to load the component. Or when the component is covered by the other components, you can use this command to refresh the covered component.

2. Component auto refresh when attribute changes only valid for those attributes in green bold font. The other attributes not in this format can only be refreshed and displayed by the command of ref.

3.When creating a component in Nextion editor, the default loading mode is auto loading. When the loading mode is set as manual loading, it requires to use ref to load. When the component is sheltered by GUI command mapping, or when the component is sheltered by other manual loading components, you can use ref to refresh the component.



click: Activate component's press/release event

click cmpID, event

cmpID: component ID or component name

event: 0 - release event; 1 - press event

  • Example
click b0, 1   //activate press event of component b0
click 2, 0   //activate release event of component 2

Remark:

1, Use "click" command to activate press/release event of a component without touch the LCD.

ref_stop: Stop refreshing screen

  • Example
ref_stop   // no parameters

Remarks:

1.If you do not want to see the whole waveform flow progress, rather, you want to view the whole waveform all at once, you can stop refreshing the screen and refresh it when all adopted points being passed through.

2.Once stop refreshing the screen, all other commands and responded attribute assign operations will still run normally, but the components on the screen will not auto-refresh, neither will any changes in component attributes be refreshed and displayed on the screen(the changes are valid). When the device receive the command ref_star, those changes will be immediately refreshed and displayed on the screen (on condition that the changes are made from the attributes in green bold font).

3.When stop refreshing the screen, ref command will still be executed. Besides, all GUI drawing instructions such as draw point, draw line will still be executed and any changes will be immediately displayed.


ref_star: Recover refreshing screen

ref_star: recover refreshing screen

  • Example
ref_star   // no parameters

Remarks:

This command should be used after ref_stop command.


get: Get variable/constant value with format

get att

att: variable name

  • Example 1
get t0.txt      //return t0's txt value
  • Example 2
get j0.val    //return J0's val value
  • Example 3
get "123"      //return constant string "123"
  • Example 4
get 123      //return constant value: 123

Remarks:

1. When returned value is a string, the returned data is 0X70+ASCII code+0xff 0xff 0xff.

2. When returned value is numerical, returned data is 0X71+4 byte binary data+0xff 0xff 0xff. The data storage mode is little-endian mode (namely, low-order in front, and high-order at back).

3. The specific returning format of data, please refer to the table: Format of Device Return Data


sendme: send current pageID to UART

  • Example:
sendme  //no parameters

Remarks:

If you want the page auto-send pageID every refresh, simply enter sendme in page initialize event.


cov: variable type conversion

cov att1,att2,lenth

att1: source variable

att2: target variable

lenth: length of the string(0 - automatic length, nonzero - fixed length)

  • Example 1:
cov h0.val,t0.txt,0  //convert the value variable of slider h0 val into decimal string and assign the txt variable of t0, the length is automatic
  • Example 2:
cov t0.txt,j0.val,0  //convert the string variable of t0 txt into value and assign the variable of slider h0 val, the length is automatic

Remarks:

1.lenth always represents the length of the string, when the value converts into string, it is the length of target variable; when the string converts into value, it is the length of source variable.

2. If the target variable and source variable are of the same type, the conversion failed.


touch_j: Touch calibration

touch_j:

  • Example:
touch_j   //Enter touch calibration function, this command does not need parameter

Remarks:

All the devices have been calibrated before packing from the factory, this command is not needed under normal circumstances



substr: Extracts the characters from a string

substr att0,att1,star,lenth

att0: A string from which a substring is to be returned

att1: Returned substring

star: The position where to start the extraction. First character is at index 0

lenth: Specifies the length of the returned string


  • Example:
 substr t0.txt,t1.txt,0,2  

Remarks:

All the devices have been calibrated before packing from the factory, this command is not needed under normal circumstances


vis: Hide/show component

vis obj,state

obj: component name or component ID

  • Example 1:
vis b0,0   //hide component b0
  • Example 2:
vis b0,1   //show component b0
  • Example 3:
vis 1,0   //hide the component whose ID is 1
  • Example 4:
vis 1,1   //show the component whose ID is 1

Remarks:

1.The first parameter 255 means all components in current page, for example: vis 255,0 (hide all components in current page); vis 255,1 (show all components in current page).


tsw: Enable/disable component touch function

tsw cmp,state

cmp: component name or component ID

state:(0=disable or 1=enable)

  • Example 1:
tsw b0,0  //component b0 touch invalid
  • Example 2:
tsw b0,1  //component b0 touch valid
  • Example 3:
tsw 1,0  //component of ID 1 touch invalid
  • Example 4:
tsw 1,1  //component of ID 1 touch valid

Remarks:

1.The first parameter 255 means all components in current page, for example: tsw 255, 0 (all components in current page touch invalid); tsw 255, 1 (all components in current page touch valid).


com_stop: Stop execute instructions from UART

  • Example:
com_stop  //no parameters

Remarks:

This command is used for pausing the execution of serial port commands, but note that the device will continue receiving the commands and store them in the buffer. Until receiving "com_star" commands, the device will execute the rest commands that store in the buffer.

When using this command to pause the execution, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.


com_star: Execute instructions from UART

  • Example:
com_star  //no parameters

Remarks:

After receiving this command, the device will execute all the commands that store in buffer and new commands form UART.

When using com_stop and com_start, please make sure whether the buffer size and the maximum capacity of command queue can store all the commands you need. You will find these two parameter in Nextion Hardware manual.


randset: Set random value range

randset minval,maxval

minval: minimum value

maxval: maximum value

  • Example:
ranset 1,100  //set current value randomly generated from 1 to 100

Remarks:

1. You should use randset to set random value generated range beforehand. Without setting randset, the value range will be 0~4294967295 by default. Aftering setting randset, you will get a new random value within the preset range every time you run rand

2. The range set by randset keeps valid unless the device being reboot or reset.


code_c: Clear the buffer

  • Example:
code_c   //no parameters

Remarks: Clear the commands that is stored in the buffer without execution.


print: Get variable variable/constant value without format

print att

att: variable name

  • Example 1:
print t0.txt //returns the txt property value of component t0 in ASCII
  • Example 2:
print j0.val //returns val’s property value of component j0 in 4-byte hexadecimal data
  • Example 3:
print "123" //returns the ASCII of string "123":0x31 0x32 0x33
  • Example 4:
print 123 //returns the 4-byte hexadecimal data of value "123":0x7B 0x00 0x00 0x00

Remarks:

1. When the variable obtained by using print command is string type, the device directly returns string ASCII; if it is numeric type (such as progress val property) , the device will directly return the variable’s 4-byte hexadecimal data, value is stored as little-endian mode (ie low level in the front, high level at the back ).

2. When use print command to obtain data, the device sends only the data content, no start identifier, nor end mark.

3.print command can match up printh command to add a piece of user-defined label in the front so as to tell the microcontroller which component this variable belongs to).

4. print command is very similar to get command, the only difference between them is get command returns data with initial identifier (0x70 or 0x71) and end mark (0xff 0xff 0xff), while print not.


printh: Send hexadecimal string

printh hex hex: the characters' hexadecimal string expression to be sent

  • Example
printh d0 a0 //let device send these two bytes 0xd0 0xa0

Remarks:

1. print and printh commands are executed only in Nextion display, they will not be shown in the software simulator.

2. When using printh command to send data, the device sends specified characters only, no Start character, Space character or End character.

3. There must have one and only Space separated between each set of characters in the parameter, both upper case and lower case are supported in the hexadecimal string expression.


add: Add data to waveform component

add objid, ch, val

objid: Waveform component ID

ch: Waveform component channel number

val: value (maximum 255, minimum 0)

  • Example 1
add 1, 0, 30  //add data 30 to channel 0 of the Waveform component which ID number is 1
  • Example 2
add 1, 1, 50  //add data 50 to channel 1 of the Waveform component which ID number is 1

Remarks:

1.Waveform component only support 8-bit values, 0 minimum, 255 maximum.

2.Each page supports up to four Waveform components, each Waveform component supports up to four channels. It supports continuously pass through data, the component will auto-flow and display the value. It supports to change attributes during passing through data, such as change the background color or foreground color for each channel during the process.


addt: Add data to waveform component in volume

addt objid, ch, qty

objid: waveform component ID

ch: channel number of waveform component

qty: adopted point quantity of the data

  • Example:
addt 1, 0, 100  //waveform component whose ID is 1 enter into data pass through mode, pass through adopted point quantity is 100

Remarks:

1.Waveform component only support 8-bit values, 0 minimum, 255 maximum. Single pass through is 1024 bits maximum.

2.After sending waveform data pass through command, it will take some time to get the device responded and started passing through values. This period takes about 5ms(it will take longer if there are other commands to be executed in the buffer zone before executing data pass through command). Following this period, it will send a data pass through ready data(0XFE+Terminator) to user, then it will start sending pass through data. The data being passed are only hexadecimal numbers. It recovers to command receiving state only after the device has adopted specified data.

3.Waveform will not refresh until specified data has been passed through completely.


cle: Clear data in waveform component

cle objid, ch

objid: waveform component ID (component name or variable is not supported); ch: channel

  • Example:
cle 1, 0   //clear the data of waveform component ID=1, channel=0;
cle 1, 255   //clear all the data of waveform component ID=1 

Remarks: ch=255: all channels

rest: Reset Nextion device

rest

Example:

 rest    //no parameters  

doevents: Force refresh the screen immediately

doevents

Example:

 doevents //no parameters

while(n0.val<1024)
{
n0.val++
doevents    //the screen will keep refreshing during the loop
}

Remark: 1, In a long looping statement, you can use doevents to avoid the screen display like brick. 2, doevents usually work with "while" or "for" statement.

strlen: check length of a string

strlen att0, att1

att0: source string variable att1: return value, length of att0

Example:

 strlen t0.txt, n0.val  //assign length of t0.txt to n0.val

Remark:

1, att0 must be string, att1 must be numeric.


if: if statement

  • Example 1: If to.txt equals to 123456, it will switch to page 1
if(t0.txt==”123456”)
{    
Page 1
}
  • Example 2: Below codes can switch content of txt of button component b0 between start and stop in press event)
if(b0.txt==”start”
{    
  b0.txt==”stop”  
} else
{ 
  b0.txt==”start”  
}
  • Example 3: Below codes can switch content of txt of button component b0 among 1, 2, 3 in press event)
if(b0.txt==”1”
{    
  b0.txt==”2”  
} else if (b0.txt==”2” )
{ 
  b0.txt==”3”  
}else
{ 
  b0.txt==”1”
}

Remarks:

1. Numerical variable supports operators: “>, <, ==, !=, >=, <=”

2. Character and String variable supports operators: “==, !=”

3. Nested “()” operator is not allowed. It does not support comparison operation, such as: if (j0.val + 1> 0).

4. Operator “()” must be paired.

5. Supports nested “if” and “else if” statement.

6.Complex expression, such as “if (j0.val+1>0)” is not supported

7.Download "if" HMI demo here: Demo

while: while statemet

Example:


//n0.val will auto-add to 100, in this process the screen will 
//not refresh the result until all the statements of this process 
//being completely executed.
while(n0.val<100)
{
n0.val++
}


//n0.val will auto-add to 100, in this process the screen will 
//keep refreshing and displaying the result of component n0.

while(n0.val<100)
{
n0.val++
doevents
}  

Remarks: 1, In the process of executing a while loop, the device will not show corresponding touch event, serial command will be received in buffer, but not executed until all the statements in the process has finished execution. Please be cautious when using this command, or it might be easily enter into endless loop. 2, It's recommended to use "doevents" command together. 3, refer to remark of "if" statement

for: for statemet

  • Examples:

//n0.val will auto-add to 100, in this process the screen will
//not refresh the result until all the statements of this process 
//being completely executed.

for(n0.val=0; n0.val<100; n0.val++)
{
}

//n0.val will auto-add to 100, in this process the screen will
// keep refreshing and displaying the result of component n0 .

for(n0.val=0; n0.val<100; n0.val++)
{
doevents   
}

repo: read EEPROM - Enhanced Model Only

repo att, add

att: variable/constant

add: storage address in EEPROM

Example:

repo t0.txt,10 // read and assign value to t0.txt, read length is (t0.txt-mal)+1
repo n0.val,10      //read and assign value to n0.val, read length is 4 bytes

Remark:

1, read a string from EEPROM, read length is length of the string+1.

2, read a numeric value from EEPROM, read length is 4 bytes.


wepo: write EEPROM - Enhanced Model Only

wepo att,add

att: variable/constant

add: storage address in EEPROM

Example:

wepo t0.txt,10 // write value of t0.txt to EEPROM, start from address #10. storage size is (t0.txt-mal)+1 bytes
wepo "abcd",10   // write string "abcd" to EEPROM, start from address #10. storage size is 5 bytes
wepo 11,10  //write constant 11 to EEPROM, start from address #10. storage size 4 bytes  

Remark:

1, Storage address start from 0byte to 1023byte.

2, Storage size of a string is 1 byte + string length; storage size of a numeric constant is 4 bytes.

3, Supported numeric data type is long integer, from -2,147,483,648 to 2,147,483,647 [v035 supports 0 to 2,147,483,647 only]


wept: write data in hex to EEPROM through UART - Enhanced Model Only

wept add, length

add: start address in EEPROM

length: length of data


Example:

wept 30, 20 // write 20 bytes of hex data from UART to EERPOM, start address is 30 

Remark:

1, When wept instruction received, Nextion device will take around 5ms to initiate and send ready signal “0xFE 0xFF 0xFF 0xFF"

2, Before you send data from UART, you should wait until you get ready signal from Nextion device

3, wept can not be terminated.



rept: read data in hex from EEPROM to UART - Enhanced Model Only

rept add, lenght

add: start address in EEPROM

length: length of data

Example:

rept 30, 20 // read 20 bytes of hex data from EEPROM to UART, start address is 30 

cfgpio: configure GPIO - Enhanced Model Only

cfgpio id,state,cmp

id: I/O pin number

state: work state of the GPIO

  0 - pull up input mode
  1 - input binding mode
  2 - push pull output mode
  3 - PWM output mode
  4 - open drain output mode

cmp: binding component, available in work state 2

Example:

cfgpio 0, 0, 0    //Configure GPIO0 as pull up input mode, you can read the input status from system variable pio0, 
                       //such as: n0.val = pio0

cfgpio 1, 2, 0   //Configure GPIO1 as push pull output mode, you can control the output level 
                 //by system variable pio1, such as: pio1 = 1

cfgpio 2, 1, b0   //Configure GPIO2 as input binding mode, the binding component is button b0. 
                  //Falling edge of GPIO2 will trigger b0's button press event, rising edge of 
                  //GPIO2 will trigger bo's button release event.

cfgpio 4, 3, 0   //Configure GPIO4 as PWM output mode, you should use system variable pwm4 
                 //to set duty cycle before you use the instruction

Remark:

1, only GPIO4 to GPIO7 support PWM function

2, When configure a GPIO to input binding mode, only components in current page can be bind. It is recommended to put the instruction in the preinitialize event, because binding event wont not be triggered after page refreshing or switching.


Classification II: GUI Designing Command

Note: When you can’t realize some special GUI designing in Nextion Editor, you can use some GUI commands to make it happen. Generally, the controls in Nextion editor can satisfy your GUI designing demand.

cls: clear the screen

cls color

color: Decimal color value or color code

  • Example 1:
cls 1024  //Refresh the screen with decimal 1024 color value
  • Example 2:
cls RED  //Refresh the screen with the color of code RED (RED represents red color)

Both Decimal color value and Color code are supported in Nextion Editor


pic: display picutres

pic x, y, picid

x: x coordinate starting point;

y: y coordinate starting point;

picid: Picture ID;

  • Example 1:
pic 10, 20, 0  //Display the picture (ID is 0) in resource file at the coordinate (10, 20)
  • Example 2:
pic 40, 50, 1  //Display the picture (ID is 1) in resource file at the coordinate (40, 50)

picq: Crop picture

picq x, y, w, h, picid

x: x coordinate starting point;

y: y coordinate starting point;

w: area width;

h: area height;

picid: Picture ID;

  • Example:
picq 20, 50, 30, 20, 0  
//Crop the area from starting coordinate (20, 50) , with a width 30×height 20 size, 
//in the picture 0 (the background picture must be full-screen) and display it on 
//the screen, and the display coordinate is the starting coordinate (20, 50).

Remarks:

This instruction requires that the background picture must be full-screen; otherwise, the image you crop is not the one you want. The crop image area and the display area is overlap on the screen.


xpic: Advanced crop picture

xpic x, y, w, h, x0, y0, picid

x: x coordinate starting point;

y: y coordinate starting point;

w: Region width;

h: Region height;

x0: crop picture starting point x coordinate;

y0: crop picture starting point y coordinate;

picid: Picture ID;


  • Example:
picq 20, 50, 30, 20, 15, 15, 0  
//Crop the area from starting coordinate (15, 15) ,
//with a width 30 × height 20 size, in the picture 0 (the background 
//picture must be full-screen) and display it on the screen, and the display
//coordinate is the starting coordinate (20, 50).




xstr: Print string on the device

xstr x, y, w, h, fontid, fontcolor, backcolor, xcenter, ycenter, sta, string

x: x coordinate starting point;

y: y coordinate starting point;

w: area width;

h: area height;

fontid: Font ID;

fontcolor: Font color;

backcolor: Background color (when set sta as Crop Image or Image, backcolor means image ID );

xcenter: Horizontal alignment (0 is left-aligned, 1 is centered, 2 is right-aligned);

ycenter: Vertical alignment (0 is upper-aligned, 1 is centered, 2 is lower-aligned);

sta: Background fill(0-crop image;1-solid color;2-Image; 3-No backcolor, when set sta as Crop Image or Image, backcolor means image ID);

string: Character content;

  • Example:
xstr 0, 0, 100, 30, 1, RED, BLACK, 1, 1, 1, "China"
  • Explanation:

Use font 1, at the starting point coordinate(0,0), write"China" in an area that its width is 100, height is 30, the font color is RED, background color is BLACK, horizontal alignment is center, and vertical alignment is center too.


Remarks:

1.There is automatic word wrapping if characters exceeds the default set w. If there are remaining characters not written out when wrapped to h, they will be neglected.

2. For more information about color value, please refer to cls command.


fill x, y, w, h, color

Fill area

x: x coordinate starting point;

y: y coordinate starting point;

w: area width;

h: area height;

color: fill color;

  • Example:
fill 0, 0, 100, 30, RED  //Fill color RED in the area of starting coordinate (0, 0) and width 100×height 30

Remarks:

For more information about color value, please refer to cls command.


line x, y, x2, y2, color

x: x coordinate starting point;

y: y coordinate starting point;

x2: x coordinate ending point;

y2: y coordinate ending point;

color: Line color;

  • Example:
line 0, 0, 100, 100, RED  //Draw a line in color RED between the coordinate (0, 0) and the coordinate (100, 100)

Remarks:

For more information about color value, please refer to cls command.


draw x, y, x2, y2, color

x: x coordinate starting point;

y: y coordinate starting point;

x2: x coordinate ending point;

y2: y coordinate ending point;

color: Line color;

  • Example:
draw 0, 0, 100, 100, RED    //Draw a rectangle, the top left coordinate is (0, 0) and bottom right corner is (100, 100), rectangle frame color is RED.

Remarks:

1. What is drawn by draw is hollow rectangle. Please directly use area fill instruction of fill if the filled rectangle needs filling. 2. For more information about color value, please refer to cls command.


cir x, y, r, color

cir x, y, r, color: draw a hollow circle

x: Coordinate x of the center of a circle

y: Coordinate y of the center of a circle

r: Radius

color: Line color;

  • Example:
cir 100, 100, 30, RED    //Draw a hollow circle whose radius is 30 with the coordinate (100, 100) as the center of a circle, circle frame line is RED

Remarks: For more information about color value, please refer to cls command.


Nextion Editor supports decimal color value and color code using in all GUI designing commands, for more information, please refer to Color Code List.

cirs x, y, r, color

cirs x, y, r, color:draw a solid circle

x: circle center x coordinate

y: circle center y coordinate

r: Radius

color: Fill color;

  • Example
cirs 100, 100, 30, RED    //Draw a solid circle whose radius is 30 with the coordinate (100, 100) as the center of a circle, circle color is RED

Remarks: For more information about color value, please refer to cls command.


Nextion HMI: System Variables List

Item Name Meaning Instance/Remarks
1 dim Current value of backlight brightness 1.dim=50 2.dim=dim+l0 3.dim=dim-l0

When you set dim=80, it means you have set the brightness as 80, but did not save it as default. Next time you power on the Nextion TFT, the brightness of backlight will keep its default setting.

2 dims default backlight brightness when Nextion is powered on 1.dims=50 2.dims=dims+10 3.dims=dims-l0

When you set dims=80 to Nextion TFT, it means you have set the brightness as 80, and have saved it as default. Next time you power on the Nextion TFT, the brightness of backlight will be 80 by default.

3 baud Current value of baud 1.baud=2400 2.baud=4800 3.baud=9600

4.baud=19200 5.baud=38400 6.baud=57600 7.baud=115200

4 bauds Default value of baud when Nextion is powered on 1.bauds=9600 is the default baud of factory settings.

2.when you set bauds=115200 to Nextion, it means you have set the baud as 115200, and saved it as default. Next time you power the Nextion, the value of baud will be 115200 by default.

5 spax Horizontal spacing of font display

(default 0)

spax=2
6 spay Vertical spacing of font display

(default 0)

spay=2
7 thc Brush color at touch drawing l.thc=RED 2.thc=l024
8 thdra Touch drawing function thdra=0(C1ose) thdra=1(Open)
9 ussp If no serial data, it will auto activate sleep time (unit: second, minimum 3, maximum 65,535, power-on default 0) ussp=30(No serial data within 30 seconds, it auto will enter into sleep mode)

ussp=0(invalid)

10 thsp If no touch operation, it will auto enter into sleep time (unit: second, minimum 3, maximum 65,535, power-on default 0) thsp=30(No touch operation within 30 seconds, it will auto enter into sleep mode)

thsp=0(invalid)

11 thup Touch in sleep mode will auto-awake switch (power-on default 0) thup=0(Touch will not auto awake switch during sleep mode)

thup=1(Touch will autom awake switch during sleep mode) Remarks: Whether thup be 0 or 1, whenever there is any touch operation in sleep mode, the device will send touch coordinates to the serial port.

12 sendxy Close or open real-time sending touch coordinate function sendxy=0(C1ose) sendxy=1(Open)

Remarks:

1. When this function is open, the device will send touch coordinate through serial port when you touch the screen. 2. Please refer to the table: Format of Device Return Data to learn more about the format of sending the coordinate.

13 delay Delay=100(Pause the device for l00ms)

Remarks: When delay command is executed, the CPU of the device will not execute any commands, but will continue receiving serial port command and store them to buffer.

14 sleep sleep=0 (Exit Sleep)

sleep=l (Enter Sleep)

Remarks:

When the device wake up from sleep mode, the device will auto refresh the current page, and the backlight brightness will recover to the default brightness value. Two commands available for changing the brightness of backlight, dim and dims.

15 bkcmd Data return of successful/failed execute serial command(2 by default) bkcmd=0 (No return)

bkcmd=l (Only return the successful data)

bkcmd=2(Only return the failed data)

bkcmd=3(Always return)

Remarks:

This setting only affects the serial command’s successful execution or fail execution’s data return. In Nextion Editor’s editing interface, when there is a command execution error, it will return error data; when the command being executed successfully, it will not return execution result data.

16 rand random value dim=rand (assign a random value to backlight brightness)

n0.val=rand (assign a random value to variable of n0.val)

Remarks:

1.Before use rand, you should use randset command to set random value generated range. If you do not set it, the default range will be 0~4294967295. Aftering setting randset, you will get a new random value within the preset range every time you run rand.

2. The range set by randset keeps valid unless the device being reboot or reset.

17 sys0

sys1

sys2

Numeric system variables sys0=10 sys1=40 sys2=60 n.val=sys2

Remarks:

ys0, sys1, sys2 are global variables, which do not required to define or create. You can use them in any page. Default value for these three variables are 0, they can be read and write, their value range are 0~4294967295. It's recommended to pass values through pages with they system variables.

18 rtc0 to rtc6 RTC variables (Enhanced Only) rtc0, year;

rtc1, month;

rtc2, day;

rtc3, hour;

rtc4, min;

rtc5, second;

rtc6, week;

19 pio0 to pio7 GPIO variables (Enhanced Only) Default mode when power on: pull up input mode

Internal pull up resistor: 50K

20 pwm4 to pwm7 Duty cycle for the PWM GPIO (Enhanced Only) min value = 0, max value = 100, default = 50;
21 pwmf PWM frequency (Enhanced Only) min value = 1Hz, max value = 65536 Hz, default = 1000Hz;

All PWM output is unified to one frequency, no independent setting is allowed.

22 wup Refresh certain page when wake up wup=255 (default, refresh current page), wup=2 (refresh page 2 when wake up)

Note: Nextion can execute wup even in sleep mode;


Nextion HMI: Color Code List

Code Decimal System Indicator Color
RED 63488 Red
BLUE 31 Blue
GRAY 33840 Gray
BLACK 0 Black
WHITE 65535 White
GREEN 2016 Green
BROWN 48192 Brown
YELLOW 65504 Yellow

Format of Device Return Data

Table 1: serial l instruction execution success or failure notification format

1.Only when the system variable bkcmd is not zero will return instruction execution succeed or fail data, bkcmd defaults to 0 after each power on, which means it does not return the result of instruction execution.

2.The code of the source file is not affected by bkcmd when software is under editing, the error data will be returned when there is an execution error, and the error data will not be returned when execute success.

3.The returned data is ended with three bytes of “0XFF 0XFF 0XFF”.

The first byte of returned data Meaning Format
0X00 Invalid instruction 0X00+End
Return this data when receiving the invalid instruction sent by the user
0X01 Successful execution of instruction 0X01+End
Return this data when the instruction sent by the user is successfully executed
0X02 Component ID invalid 0X02+End
Return this data when the instruction from external device contains invalid component ID or invalid component name
0X03 Page ID invalid 0X03+End
Return this data when the instruction sent by external device contains invalid page ID or invalid page name
0X04 Picture ID invalid 0X04+End
Return this data when the instruction sent by the user contains invalid picture ID
0X05 Font ID invalid 0X05+End
Return this data when the instruction sent by the user contains invalid font ID
0X11 Baud rate setting invalid 0X11+End
The baud rate setting instruction sent by the user contains invalid baud rate parameter
Baud rate supported by the device including:2400 4800 9600 19200 38400 57600 115200
0X12 Curve control ID number or channel number is invalid 0X12+End
When users use the add commands to add data to curve, this data will be returned as curve control ID number or channel number is invalid
0X1A Variable name invalid 0X1A+End
Return this data when the serial port receives invalid variable name
Note: control attribute is also called variable. For example, when you set the attribute of a control, it will return this data if the unavailable attribute name is input.
0X1B Variable operation invalid 0X1B+End
For example, when txt attribute of text component t0 is assigned, it should be written as t0.txt=“abc” It is wrong if you write t0.txt=abc.
For another example, the val attribute of progress bar j0 should be numerical, so it should be written as j0.val=50; it will be wrong if you write j0.val=“50” or j0.val=abc.
0X1C Failed to assign 0X1C+End

Return this data when attribute failed to assign.

0X1D Operate EEPROM failed 0X1D+End

Return this data when operate EEPROM failed.

0X1E Parameter quantity invalid 0X1E+End

Return this data when the instruction parameter quantity input by user is wrong.

0X1F IO operation failed 0X1F+End

Return this data when operate IO failed.

0X20 Undefined escape characters 0X20+End

Return this data when you use a undefined escape character.

0X23 Too long variable name 0X23+End

Maximum allowed length of a variable is 29 characters.

Table 2: other data return format

1.The returned data is end with three bytes of “0XFF 0XFF 0XFF”.

2.The following data’s return does not be affected by bkcmd.

The first byte of returned data Meaning Format
0X65 Touch event return data 0X65+Page ID+Component ID+TouchEvent+End
Return this data when the touch event created by the user is pressed.
Definition of TouchEvent: Press Event 0x01, Release Event 0X00)
Instance: 0X65 0X00 0X02 0X01 0XFF 0XFF 0XFF'
Meaning: Page 0, Button 2, Press
0X66 Current page ID number returns 0X66+Page ID+End
The device returns this data after receiving “sendme” instruction)
Instance: 0X66 0X02 0XFF 0XFF 0XFF
Meaning: Current page ID is 2
0X67 Touch coordinate data returns 0X67++ Coordinate X High-order+Coordinate X Low-order+Coordinate Y High-order+Coordinate Y Low-order+TouchEvent State+End
When the system variable “sendxy” is 1, return this data at TouchEvent occurring
Definition of TouchEvent: Press Event 0x01, Release Event 0X00
Instance: 0X67 0X00 0X7A 0X00 0X1E 0X01 0XFF 0XFF 0XFF
Meaning: Coordinate (122,30), Touch Event: Press
0X68 Touch Event in sleep mode 0X68++Coordinate X High-order+Coordinate X Low-order+Coordinate Y High-order+Coordinate Y Low-order+TouchEvent State+End
When the device enters sleep mode, return this data at TouchEvent occurring
Definition of TouchEvent: Press Event 0x01, Release Event 0X00
Instance: 0X68 0X00 0X7A 0X00 0X1E 0X01 0XFF 0XFF 0XFF
Meaning: Coordinate (122,30), Touch Event: Press
0X70 String variable data returns 0X70+Variable Content in ASCII code+End
When the variable obtained through get command is string type, return this data
Instance: 0X70 0X61 0X62 0X63 0XFF 0XFF 0XFF
Meaning: Return the string data: “abc”
0X71 Numeric variable data returns 0X71+variable binary data(4 bytes little endian mode, low in front)+End
When the variable obtained by get command is value, this data returns.
Instance:0X71 0X66 0X00 0X00 0X00 0XFF 0XFF 0XFF
Meaning:return value data:102
0X86 Device automatically enters into sleep mode 0X86+End

Only when the device automatically enters into sleep mode will return this data. If execute serial command “sleep = 1” to enter into sleep mode, it will not return this data.

0X87 Device automatically wake up 0X87+End

Only when the device automatically wake up will return this data. If execute serial command “sleep=0” to wake up, it will not return this data.

0X88 System successful start up This data is sent after a successful power-on initialization on the device
0X89 Start SD card upgrade This data is sent after the device power on and detect SD card, and then enter upgrade interface
0XFD Data transparent transmit finished 0xFD+End
OXFE Data transparent transmit ready The device will enter into transparent transmission data initialization mode after receiving data transparent transmission instruction. Data will be sent once the initialization is completed, which means it has entered into data transparent transmission mode and start to transparent transmit data.

Useful link