Difference between revisions of "BT Shield (Master Slave)"
(→11. Set/Check -- Query access patterns) |
(→Overview) |
||
(25 intermediate revisions by the same user not shown) | |||
Line 6: | Line 6: | ||
it can directly plug on Arduino/IFlat-32 board, use UART port for | it can directly plug on Arduino/IFlat-32 board, use UART port for | ||
communication with Arduino/IFlat-32 or PC. | communication with Arduino/IFlat-32 or PC. | ||
+ | |||
+ | Go shopping [http://imall.iteadstudio.com/im120417010.html BT Shield (Master Slave) (IM120417010)] | ||
==Specifications== | ==Specifications== | ||
Line 275: | Line 277: | ||
===12. Set/Check PIN code:=== | ===12. Set/Check PIN code:=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+PSWD=<Param>||OK||Param: PIN code (Default 1234) | ||
+ | |- | ||
+ | | AT+ PSWD?||+ PSWD :<Param> OK ||Param: PIN code (Default 1234) | ||
+ | |} | ||
===13. Set/Check serial parameter:=== | ===13. Set/Check serial parameter:=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+UART=<Param>,<Param2>,<Param3>||OK||Param1: Baud Param2: Stop bit Param3: Parity | ||
+ | |- | ||
+ | | AT+UART?||+UART=<Param>,<Param2>, <Param3> OK ||Param1: Baud Param2: Stop bit Param3: Parity | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+UART=115200,1,2,\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+UART? | ||
+ | |||
+ | +UART:115200,1,2 | ||
+ | |||
+ | OK | ||
===14. Set/Check connect mode:=== | ===14. Set/Check connect mode:=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+CMODE=<Param> ||OK||Param: 0 - connect fixed address 1 - connect any | ||
+ | address 2 - slave-Loop | ||
+ | |- | ||
+ | | AT+ CMODE? ||+ CMODE:<Param> OK||Param: 0 - connect fixed address 1 - connect any address 2 - slave-Loop | ||
+ | |} | ||
===15. Set/Check fixed address:=== | ===15. Set/Check fixed address:=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+BIND=<Param>||OK||Param: Fixed address (Default 00:00:00:00:00:00) | ||
+ | |- | ||
+ | | AT+ BIND?||+ BIND:<Param> OK||Param: Fixed address (Default 00:00:00:00:00:00) | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+BIND=1234,56,abcdef\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+BIND?\r\n | ||
+ | |||
+ | +BIND:1234:56:abcdef | ||
+ | |||
+ | OK | ||
===16. Set/Check LED I/O=== | ===16. Set/Check LED I/O=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+POLAR=<Param1,<Param2>||OK||Param1: 0- PIO8 low drive LED 1- PIO8 high drive | ||
+ | LED Param2: 0- PIO9 low drive LED 1- PIO9 high drive LED | ||
+ | |- | ||
+ | | AT+ POLAR? ||+ POLAR=<Param1>,<Param2> OK ||Param1: 0- PIO8 low drive LED 1- PIO8 high drive LED Param2: 0- PIO9 low drive LED 1- PIO9 high drive LED | ||
+ | |} | ||
===17. Set PIO output=== | ===17. Set PIO output=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+PIO=<Param1>,<Param2>||OK||Param1: PIO number Param2: PIO level 0- low 1- high | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | 1. PIO10 output high level | ||
+ | |||
+ | AT+PI0=10,1\r\n | ||
+ | |||
+ | OK | ||
===18. Set/Check – scan parameter=== | ===18. Set/Check – scan parameter=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+IPSCAN=<Param1>,<Param2>,<Param3>,<Param4>||OK||Param1: Query time interval | ||
+ | Param2 : Query duration Param3 : Paging interval Param4 : Call duration | ||
+ | |- | ||
+ | | AT+IPSCAN? ||+IPSCAN:<Param1>,<Param2>,<Param3>,<Param4> OK ||Param1: Query time interval Param2 : Query duration Param3 : Paging interval Param4 : Call duration | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+IPSCAN =1234,500,1200,250\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+IPSCAN? | ||
+ | |||
+ | +IPSCAN:1234,500,1200,250 | ||
===19. Set/Check – SHIFF parameter=== | ===19. Set/Check – SHIFF parameter=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+SNIFF=<Param1>,<Param2>,<Param3>,<Param4>||OK||Param1: Max time Param2: Min time Param3: Retry time Param4: Time out | ||
+ | |- | ||
+ | | AT+ SNIFF?||+SNIFF:<Param1>,<Param2>,<Param3>,<Param4> OK||Param1: Max time Param2: Min time Param3: Retry time Param4: Time out | ||
+ | |} | ||
===20. Set/Check security mode=== | ===20. Set/Check security mode=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+SENM=<Param1>,<Param2>||1. OK 2. FAIL ||Param1: | ||
+ | |||
+ | 0——sec_mode0+off | ||
+ | |||
+ | 1——sec_mode1+ | ||
+ | non_secure | ||
+ | |||
+ | 2——sec_mode2_ | ||
+ | service | ||
+ | |||
+ | 3——sec_mode3_l | ||
+ | ink | ||
+ | |||
+ | 4——sec_mode_u | ||
+ | nknown | ||
+ | |||
+ | Param2: | ||
+ | |||
+ | 0——hci_enc_mod | ||
+ | e_off | ||
+ | |||
+ | 1——hci_enc_mod | ||
+ | e_pt_to_pt | ||
+ | |||
+ | 2——hci_enc_mod | ||
+ | e_pt_to_pt_and_b | ||
+ | cast | ||
+ | |- | ||
+ | | AT+ SENM?||+ SENM:<Param1>,<Param2> OK ||Param1: | ||
+ | |||
+ | 0——sec_mode0+off | ||
+ | |||
+ | 1——sec_mode1+ | ||
+ | non_secure | ||
+ | |||
+ | 2——sec_mode2_ | ||
+ | service | ||
+ | |||
+ | 3——sec_mode3_l | ||
+ | ink | ||
+ | |||
+ | 4——sec_mode_u | ||
+ | nknown | ||
+ | |||
+ | Param2: | ||
+ | |||
+ | 0——hci_enc_mod | ||
+ | e_off | ||
+ | |||
+ | 1——hci_enc_mod | ||
+ | e_pt_to_pt | ||
+ | |||
+ | 2——hci_enc_mod | ||
+ | e_pt_to_pt_and_b | ||
+ | cast | ||
+ | |} | ||
===21. Delete Authenticated Device=== | ===21. Delete Authenticated Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+PMSAD=<Param>||OK||Param: Authenticated Device Address | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+PMSAD =1234,56,abcdef\r\n | ||
+ | |||
+ | OK | ||
===22. Delete All Authenticated Device=== | ===22. Delete All Authenticated Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ RMAAD||OK||- | ||
+ | |} | ||
===23. Search Authenticated Device=== | ===23. Search Authenticated Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+FSAD=<Param>||1. OK 2. FAIL ||Param: Device address | ||
+ | |} | ||
===24. Get Authenticated Device Count=== | ===24. Get Authenticated Device Count=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ADCN?||+ADCN:<Param> OK||Param: Device Count | ||
+ | |} | ||
===25. Most Recently Used Authenticated Device=== | ===25. Most Recently Used Authenticated Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+MRAD? ||+ MRAD:<Param> OK ||Param: Recently Authenticated Device Address | ||
+ | |} | ||
===26. Get the module working state=== | ===26. Get the module working state=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ STATE? ||+ STATE:<Param> OK||Param: "INITIALIZED" "READY" "PAIRABLE" "PAIRED" "INQUIRING" "CONNECTING" "CONNECTED""DISCONNECTED" "NUKNOW" | ||
+ | |} | ||
===27. Initialize the SPP profile lib=== | ===27. Initialize the SPP profile lib=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+INIT||1. OK 2. FAIL||- | ||
+ | |} | ||
===28. Inquiry Bluetooth Device=== | ===28. Inquiry Bluetooth Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+INQ ||+INQ: <Param1>, <Param2>, <Param3> …. OK ||Param1:Address Param2 : Device Class Param3 : RSSI Signal strength | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+INIT\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+IAC=9e8b33\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+CLASS=0\r\n | ||
+ | |||
+ | AT+INQM=1,9,48\r\n | ||
+ | |||
+ | At+INQ\r\n | ||
+ | |||
+ | +INQ:2:72:D2224,3E0104,FFBC | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFC1 | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFC0 | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFC1 | ||
+ | |||
+ | +INQ:2:72:D2224,3F0104,FFAD | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFBE | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFC2 | ||
+ | |||
+ | +INQ:1234:56:0,1F1F,FFBE | ||
+ | |||
+ | +INQ:2:72:D2224,3F0104,FFBC | ||
+ | |||
+ | OK | ||
===29. Cancel Inquiring Bluetooth Device=== | ===29. Cancel Inquiring Bluetooth Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ INQC||OK||- | ||
+ | |} | ||
===30. Equipment Matching=== | ===30. Equipment Matching=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+PAIR=<Param1>,<Param2>||1. OK 2. FAIL||Param1 :Device Address Param2:Time out | ||
+ | |} | ||
===31. Connect Device=== | ===31. Connect Device=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+LINK=<Param>||1. OK 2. FAIL||Param : Device Address | ||
+ | |} | ||
+ | |||
+ | '''Example:''' | ||
+ | |||
+ | AT+FSAD=1234,56,abcdef\r\n | ||
+ | |||
+ | OK | ||
+ | |||
+ | AT+LINK=1234,56,abcdef\r\n | ||
+ | |||
+ | OK | ||
===32. Disconnect=== | ===32. Disconnect=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+DISC||1. +DISC:SUCCESS OK 2. +DISC:LINK_LOSS OK 3. +DISC:NO_SLC OK 4. +DISC:TIMEOUT OK 5. +DISC:ERROR OK||Param : Device Address | ||
+ | |} | ||
===33. Energy-saving mode=== | ===33. Energy-saving mode=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ENSNIFF=<Param>||OK||Param : Device Address | ||
+ | |} | ||
===34. Exerts Energy-saving mode=== | ===34. Exerts Energy-saving mode=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | align="center" style="background:#f0f0f0;"|'''Command''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Respond''' | ||
+ | | align="center" style="background:#f0f0f0;"|'''Parameter''' | ||
+ | |- | ||
+ | | AT+ EXSNIFF =<Param>||OK||Param : Device Address | ||
+ | |} | ||
− | '''Application Example''' | + | '''Application Example''' |
+ | |||
This is a demo that HC-05 is a master device and communicates to | This is a demo that HC-05 is a master device and communicates to | ||
hc-06. | hc-06. | ||
Line 335: | Line 687: | ||
==Download== | ==Download== | ||
+ | [ftp://imall.iteadstudio.com/IM120417010_BT_Shield_v2.2/DS_IM120417010_BTShield.pdf Datasheet for BT Shield] | ||
+ | |||
+ | [ftp://imall.iteadstudio.com/IM120417010_BT_Shield_v2.2/DS_BluetoothHC05.pdf Datasheet for BluetoothHC05] | ||
+ | |||
+ | [ftp://imall.iteadstudio.com/IM120417010_BT_Shield_v2.2/SCH_IM120417010_BTShield.pdf Schematic for BT Shield] | ||
==Useful Links== | ==Useful Links== | ||
+ | [http://home.comcast.net/~tomhorsley/hardware/arduino/datasheet.html by Tom <The Missing BT Shield Datasheet>] | ||
+ | |||
+ | [http://forum.arduino.cc/index.php/topic,90048.msg676100.html#msg676100 by And1G <How to work with AT-Command?>] | ||
+ | |||
+ | [http://blog.iteadstudio.com/upload-program-to-arduino-with-bt-shield/ <Upload Program To Arduino With BT Shield>] |
Latest revision as of 06:07, 11 June 2014
Contents
- 1 Overview
- 2 Specifications
- 3 Electrical Characteristics
- 4 Hardware
- 5 AT command
- 5.1 1. Test command:
- 5.2 2. Reset
- 5.3 3. Get firmware version
- 5.4 4. Restore default
- 5.5 5. Get module address
- 5.6 6. Set/Check module name:
- 5.7 7. Get the Bluetooth device name:
- 5.8 8. Set/Check module mode:
- 5.9 9. Set/Check device class
- 5.10 10. Set/Check GIAC (General Inquire Access Code)
- 5.11 11. Set/Check -- Query access patterns
- 5.12 12. Set/Check PIN code:
- 5.13 13. Set/Check serial parameter:
- 5.14 14. Set/Check connect mode:
- 5.15 15. Set/Check fixed address:
- 5.16 16. Set/Check LED I/O
- 5.17 17. Set PIO output
- 5.18 18. Set/Check – scan parameter
- 5.19 19. Set/Check – SHIFF parameter
- 5.20 20. Set/Check security mode
- 5.21 21. Delete Authenticated Device
- 5.22 22. Delete All Authenticated Device
- 5.23 23. Search Authenticated Device
- 5.24 24. Get Authenticated Device Count
- 5.25 25. Most Recently Used Authenticated Device
- 5.26 26. Get the module working state
- 5.27 27. Initialize the SPP profile lib
- 5.28 28. Inquiry Bluetooth Device
- 5.29 29. Cancel Inquiring Bluetooth Device
- 5.30 30. Equipment Matching
- 5.31 31. Connect Device
- 5.32 32. Disconnect
- 5.33 33. Energy-saving mode
- 5.34 34. Exerts Energy-saving mode
- 6 Download
- 7 Useful Links
Overview
BT shield V2.2 is a serial port Bluetooth module (with master and slave mode) breakout board, it’s compatible with Arduino and IFlat-32, it can directly plug on Arduino/IFlat-32 board, use UART port for communication with Arduino/IFlat-32 or PC.
Go shopping BT Shield (Master Slave) (IM120417010)
Specifications
Microprocessor | CSR BC417 |
PCB size | 53.3mm X 47mm X 1.6mm |
Indicators | PWR,State |
Power supply | 5V DC |
IO | 6 |
Communication Protocol | UART/Bluetooth 2.0 |
RoSH | Yes |
Electrical Characteristics
Specification | Min | Type | Max | Unit |
Power Voltage | 4.5 | 5 | 5.5 | VDC |
Input Voltage VH (Target Voltage = 3.3V) | 3 | 3.3 | 3.6 | VDC |
Input Voltage VH (Target Voltage = 5V) | 4.5 | 5 | 5.5 | V |
Input Voltage VL: | -0.3 | 0 | 0.5 | V |
Current Consumption | - | 20 | 40 | mA |
Hardware
UART Multiplexer (For free UART connection setting)
You can use the jumper to connect the TXD and RXD pins of HC-05 to D0, D1, D4~D7 pin of Arduino.
When using the connection as Figure 3, the BT shield connects to the ATMega328 chip on board.
When using the connection as Figure 4, the HC-05 connects with the FT232RL chip, and the FT232RL connect to PC by USB. Whit this configuration you can use the serial software on PC to control or configure the HC-05 module.
Except the 2 configurations above, you can connect the TXD and RXD to any other pins from D4-D7, and using the software-serial library to control the HC-05 module.
Mode Switch
The Mode Set Switch is connected to PIO11, when it is pushed to CMD and powered on, the HC-05 enter command mode, HC-05 module can receive and response AT command in this mode. When it is pushed to DATA and powered on. The HC-05 enters data mode and will not accept AT command.
States LED
When power on and disconnect the port, states LED blinks 1time/2s ; when the module connect and open the serial port, states LED blinks 2times/s.
AT command
1. Test command:
Command | Respond | Parameter |
AT | OK | - |
2. Reset
Command | Respond | Parameter |
AT+RESET | OK | - |
3. Get firmware version
Command | Respond | Parameter |
AT+VERSION? | +VERSION:<Param> OK | Param : firmware version |
Example:
AT+VERSION?\r\n
+VERSION:2.0-20100601
OK
4. Restore default
Command | Respond | Parameter |
AT+ORGL | OK | - |
Default state:
Slave mode, pin code :1234, device name: H-C-2010-06-01 ,Baud 38400bits/s.
5. Get module address
Command | Respond | Parameter |
AT+ADDR? | +ADDR:<Param> OK | Param: address of Bluetooth module |
Bluetooth address: NAP: UAP : LAP
Example:
AT+ADDR?\r\n
+ADDR:1234:56:abcdef
OK
6. Set/Check module name:
Command | Respond | Parameter |
AT+NAME=<Param> | OK | Param: Bluetooth module name (Default :HC-05) |
AT+NAME? | +NAME:<Param> OK (/FAIL) | Param: Bluetooth module name (Default :HC-05) |
Example:
AT+NAME=HC-05\r\n set the module name to HC-05
OK
AT+NAME=ITeadStudio\r\n
OK
AT+NAME?\r\n
+NAME: ITeadStudio
OK
7. Get the Bluetooth device name:
Command | Respond | Parameter |
AT+RNAME?<Param1> | 1. +NAME:<Param2> OK 2. FAIL | Param1,Param 2 : the address of Bluetooth device |
Example: (Device address 00:02:72:od:22:24,name:ITead)
AT+RNAME? 0002,72,od2224\r\n
+RNAME:ITead
OK
8. Set/Check module mode:
Command | Respond | Parameter |
AT+ROLE=<Param> | OK | Param: 0- Slave 1-Master 2-Slave-Loop |
AT+ ROLE? | +ROLE:<Param> OK | Param: 0- Slave 1-Master 2-Slave-Loop |
9. Set/Check device class
Command | Respond | Parameter |
AT+CLASS=<Param> | OK | Param: Device Class |
AT+ CLASS? | 1. +CLASS:<Param> OK 2. FAIL | Param: Device Class |
10. Set/Check GIAC (General Inquire Access Code)
Command | Respond | Parameter |
AT+IAC=<Param> | 1.OK 2. FAIL | Param: GIAC (Default : 9e8b33) |
AT+IAC | +IAC:<Param> OK | Param: GIAC (Default : 9e8b33) |
Example:
AT+IAC=9e8b3f\r\n
OK
AT+IAC?\r\n
+IAC: 9e8b3f
OK
11. Set/Check -- Query access patterns
Command | Respond | Parameter |
AT+INQM=<Param>,<Param2>, <Param3> | 1.OK 2. FAIL | Param: 0——inquiry_mode_standard 1——inquiry_mode_rssi Param2: Maximum number of Bluetooth devices to respond to Param3: Timeout (1-48 : 1.28s to 61.44s) |
AT+ INQM? | +INQM :<Param>,<Param2>, <Param3> OK | Param: 0——inquiry_mode_standard 1——inquiry_mode_rssi Param2: Maximum number of Bluetooth devices to respond to Param3: Timeout (1-48 : 1.28s to 61.44s) |
Example:
AT+INQM=1,9,48\r\n
OK
AT+INQM\r\n
+INQM:1, 9, 48
OK
12. Set/Check PIN code:
Command | Respond | Parameter |
AT+PSWD=<Param> | OK | Param: PIN code (Default 1234) |
AT+ PSWD? | + PSWD :<Param> OK | Param: PIN code (Default 1234) |
13. Set/Check serial parameter:
Command | Respond | Parameter |
AT+UART=<Param>,<Param2>,<Param3> | OK | Param1: Baud Param2: Stop bit Param3: Parity |
AT+UART? | +UART=<Param>,<Param2>, <Param3> OK | Param1: Baud Param2: Stop bit Param3: Parity |
Example:
AT+UART=115200,1,2,\r\n
OK
AT+UART?
+UART:115200,1,2
OK
14. Set/Check connect mode:
Command | Respond | Parameter |
AT+CMODE=<Param> | OK | Param: 0 - connect fixed address 1 - connect any
address 2 - slave-Loop |
AT+ CMODE? | + CMODE:<Param> OK | Param: 0 - connect fixed address 1 - connect any address 2 - slave-Loop |
15. Set/Check fixed address:
Command | Respond | Parameter |
AT+BIND=<Param> | OK | Param: Fixed address (Default 00:00:00:00:00:00) |
AT+ BIND? | + BIND:<Param> OK | Param: Fixed address (Default 00:00:00:00:00:00) |
Example:
AT+BIND=1234,56,abcdef\r\n
OK
AT+BIND?\r\n
+BIND:1234:56:abcdef
OK
16. Set/Check LED I/O
Command | Respond | Parameter |
AT+POLAR=<Param1,<Param2> | OK | Param1: 0- PIO8 low drive LED 1- PIO8 high drive
LED Param2: 0- PIO9 low drive LED 1- PIO9 high drive LED |
AT+ POLAR? | + POLAR=<Param1>,<Param2> OK | Param1: 0- PIO8 low drive LED 1- PIO8 high drive LED Param2: 0- PIO9 low drive LED 1- PIO9 high drive LED |
17. Set PIO output
Command | Respond | Parameter |
AT+PIO=<Param1>,<Param2> | OK | Param1: PIO number Param2: PIO level 0- low 1- high |
Example:
1. PIO10 output high level
AT+PI0=10,1\r\n
OK
18. Set/Check – scan parameter
Command | Respond | Parameter |
AT+IPSCAN=<Param1>,<Param2>,<Param3>,<Param4> | OK | Param1: Query time interval
Param2 : Query duration Param3 : Paging interval Param4 : Call duration |
AT+IPSCAN? | +IPSCAN:<Param1>,<Param2>,<Param3>,<Param4> OK | Param1: Query time interval Param2 : Query duration Param3 : Paging interval Param4 : Call duration |
Example:
AT+IPSCAN =1234,500,1200,250\r\n
OK
AT+IPSCAN?
+IPSCAN:1234,500,1200,250
19. Set/Check – SHIFF parameter
Command | Respond | Parameter |
AT+SNIFF=<Param1>,<Param2>,<Param3>,<Param4> | OK | Param1: Max time Param2: Min time Param3: Retry time Param4: Time out |
AT+ SNIFF? | +SNIFF:<Param1>,<Param2>,<Param3>,<Param4> OK | Param1: Max time Param2: Min time Param3: Retry time Param4: Time out |
20. Set/Check security mode
Command | Respond | Parameter |
AT+SENM=<Param1>,<Param2> | 1. OK 2. FAIL | Param1:
0——sec_mode0+off 1——sec_mode1+ non_secure 2——sec_mode2_ service 3——sec_mode3_l ink 4——sec_mode_u nknown Param2: 0——hci_enc_mod e_off 1——hci_enc_mod e_pt_to_pt 2——hci_enc_mod e_pt_to_pt_and_b cast |
AT+ SENM? | + SENM:<Param1>,<Param2> OK | Param1:
0——sec_mode0+off 1——sec_mode1+ non_secure 2——sec_mode2_ service 3——sec_mode3_l ink 4——sec_mode_u nknown Param2: 0——hci_enc_mod e_off 1——hci_enc_mod e_pt_to_pt 2——hci_enc_mod e_pt_to_pt_and_b cast |
21. Delete Authenticated Device
Command | Respond | Parameter |
AT+PMSAD=<Param> | OK | Param: Authenticated Device Address |
Example:
AT+PMSAD =1234,56,abcdef\r\n
OK
22. Delete All Authenticated Device
Command | Respond | Parameter |
AT+ RMAAD | OK | - |
23. Search Authenticated Device
Command | Respond | Parameter |
AT+FSAD=<Param> | 1. OK 2. FAIL | Param: Device address |
24. Get Authenticated Device Count
Command | Respond | Parameter |
AT+ADCN? | +ADCN:<Param> OK | Param: Device Count |
25. Most Recently Used Authenticated Device
Command | Respond | Parameter |
AT+MRAD? | + MRAD:<Param> OK | Param: Recently Authenticated Device Address |
26. Get the module working state
Command | Respond | Parameter |
AT+ STATE? | + STATE:<Param> OK | Param: "INITIALIZED" "READY" "PAIRABLE" "PAIRED" "INQUIRING" "CONNECTING" "CONNECTED""DISCONNECTED" "NUKNOW" |
27. Initialize the SPP profile lib
Command | Respond | Parameter |
AT+INIT | 1. OK 2. FAIL | - |
28. Inquiry Bluetooth Device
Command | Respond | Parameter |
AT+INQ | +INQ: <Param1>, <Param2>, <Param3> …. OK | Param1:Address Param2 : Device Class Param3 : RSSI Signal strength |
Example:
AT+INIT\r\n
OK
AT+IAC=9e8b33\r\n
OK
AT+CLASS=0\r\n
AT+INQM=1,9,48\r\n
At+INQ\r\n
+INQ:2:72:D2224,3E0104,FFBC
+INQ:1234:56:0,1F1F,FFC1
+INQ:1234:56:0,1F1F,FFC0
+INQ:1234:56:0,1F1F,FFC1
+INQ:2:72:D2224,3F0104,FFAD
+INQ:1234:56:0,1F1F,FFBE
+INQ:1234:56:0,1F1F,FFC2
+INQ:1234:56:0,1F1F,FFBE
+INQ:2:72:D2224,3F0104,FFBC
OK
29. Cancel Inquiring Bluetooth Device
Command | Respond | Parameter |
AT+ INQC | OK | - |
30. Equipment Matching
Command | Respond | Parameter |
AT+PAIR=<Param1>,<Param2> | 1. OK 2. FAIL | Param1 :Device Address Param2:Time out |
31. Connect Device
Command | Respond | Parameter |
AT+LINK=<Param> | 1. OK 2. FAIL | Param : Device Address |
Example:
AT+FSAD=1234,56,abcdef\r\n
OK
AT+LINK=1234,56,abcdef\r\n
OK
32. Disconnect
Command | Respond | Parameter |
AT+DISC | 1. +DISC:SUCCESS OK 2. +DISC:LINK_LOSS OK 3. +DISC:NO_SLC OK 4. +DISC:TIMEOUT OK 5. +DISC:ERROR OK | Param : Device Address |
33. Energy-saving mode
Command | Respond | Parameter |
AT+ENSNIFF=<Param> | OK | Param : Device Address |
34. Exerts Energy-saving mode
Command | Respond | Parameter |
AT+ EXSNIFF =<Param> | OK | Param : Device Address |
Application Example
This is a demo that HC-05 is a master device and communicates to hc-06.
Step 1. Push the mode switch to CMD
Step 2. Power on, module enter command state
Step 3. Using baud rate 38400, send the ―AT+ROLE=1\r\n‖ to module, with ―OK\r\n‖ means setting successes.
Step 4. Send ―AT+CMODE=1\r\n‖, set HC-05 connect to any address, with ―OK\r\n‖ means setting successes.
Download
Useful Links
by Tom <The Missing BT Shield Datasheet>